Download Print this page
York AHR18B3XH21 Technical Manual

York AHR18B3XH21 Technical Manual

Single piece air handlers for use with split-system cooling & heat pumps
Hide thumbs Also See for AHR18B3XH21:

Advertisement

Quick Links

TECHNICAL GUIDE
SINGLE PIECE AIR HANDLERS
FOR USE WITH SPLIT-SYSTEM
COOLING & HEAT PUMPS
MODELS: AHR18 THRU 60*
Due to continuous product improvement,
specifications are subject to change without notice.
Visit us on the web at:
www.york.com
Additional rating information can be found at:
www.ahridirectory.org
WARRANTY
Standard 5-year limited parts warranty.
Extended 10-year limited parts warranty when product is
registered online within 90 days of purchase for replace-
ment or closing for new home construction.
FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE
DESCRIPTION
This fan coil line offers the ultimate in application flexibility. The
AHR (non-variable speed motor) models are shipped as upflow
models, that can be installed in upflow, horizontal right or left
without the need for additional field installed kits.
All JCI Unitary Products air handlers and coils use a TXV to pro-
vide our customers with the optimum performance and refriger-
ant control. Air handlers are shipped with "Flex-coils" without a
factory installed metering device. For added flexibility, an R-22
or R-410A TXV or orifice can be field installed to meet your
refrigerant choice.
FEATURES
Thermal Expansion Valve - Provides the ultimate refrigerant
control required for today's high efficient product. The UPG bolt-
on TXV provides the added flexibility to convert the air handler
to the required refrigerant. The UPG TXV is a true bolt-on which
does not require brazing to replace or install.
Insulated Cabinet - All air handler cabinets are thermally insu-
lated with 3/4" foil faced insulation to prevent sweating.
Factory Sealed - Achieves 2% or less total airflow leakage rate
at duct blaster field test conditions for system airflow verifica-
tion.
Durable Finish Inside and Out - Air handler casings are made
of pre-painted galvanized steel which provides a better paint to
steel bond that resists corrosion and rust creep. All internal coil
sheet metal parts are made of G60 galvanized or prepainted
G30 galvanized.
Filters - All models have internal filter racks provided for use
with 1" thick standard size filters.
Electric Heat Kits - New 6HK series of field installed electric
heat kits are available for installation friendly and easy service
applications. These 6HK kits are unique to these new models.
ISO 9001
Certified Quality
Management System
680206-YTG-C-0612

Advertisement

loading

Summary of Contents for York AHR18B3XH21

  • Page 1 Certified Quality Management System Due to continuous product improvement, specifications are subject to change without notice. Visit us on the web at: www.york.com Additional rating information can be found at: www.ahridirectory.org WARRANTY Standard 5-year limited parts warranty. Extended 10-year limited parts warranty when product is registered online within 90 days of purchase for replace- ment or closing for new home construction.
  • Page 2: Dimensions & Duct Connection Dimensions

    Tube Models Application Coil Size Conn. Types (Sq. Ft.) Deep Per In. Geometry Dia. Type AHR18B3XH21 ( Cooling /Heat Pump Sweat 3.40 (2) 14 x 17.5 1 x 0.866 Enhanced AHR24B3XH21 ( Cooling /Heat Pump Sweat 3.90 (2) 16 x 17.5 1 x 0.866...
  • Page 3: Cooling Capacity

    Rated CFM (Dry/Wet Bulb) 35/107.9 40/118.9 45/130.7 50/143.3 FULL-CASED “A” TYPE MULTI-POSITION 85/72 40.7 35.6 30.5 24.1 80/67 35.0 29.5 23.9 18.6 AHR18B3XH21 75/62 27.9 22.7 18.1 12.4 70/57 22.1 19.8 16.9 14.1 85/72 47.9 42.4 36.8 29.9 80/67 40.9 35.2...
  • Page 4 60 Hertz Size A.W.G. Amps/Type 208V 230V 208V 230V AHR MODELS AHR18B3XH21 AHR24B3XH21 AHR30B3XH21 AHR36B3XH21 AHR42C3XH21 AHR48D3XH21 AHR60D3XH21 1. OCP = Over Current Protection device, must be HACR type Circuit Breaker or Time Delay fuse. May be 0 (no Circuit Breaker) or 1 (with Circuit Breaker).
  • Page 5 PSC Min. Models W1 Only W1 + W2 Models* Speed Tap 208V 230V 208V 230V 208V 230V 208V 230V 6HK*6500206 6HK*6500506 12.3 15.0 AHR18B3XH21 6HK*6500806 19.7 24.0 6HK*6501006 24.6 29.9 6HK*6500206 6HK*6500506 12.3 15.0 6HK*6500806 19.7 24.0 AHR24B3XH21 6HK*6501006 24.6 29.9...
  • Page 6 75°C Wire Size - AWG Max. O.C.P. Amps/Type Models* 240V 208V 230V 208V 230V 208V 230V 6HK*6500206 10.0 12.42 13.73 6HK*6500506 20.0 23.25 25.71 AHR18B3XH21 6HK*6500806 32.0 36.25 40.08 6HK*6501006 40.0 44.92 49.67 6HK*6500206 10.0 12.42 13.73 6HK*6500506 20.0 23.25 25.71 6HK*6500806 32.0 36.25...
  • Page 7 680206-YTG-C-0612 ELECTRICAL DATA - (FOR MULTI-SOURCE POWER SUPPLY) - COPPER WIRE - 208/230-1-60 Min. Circuit Ampacity 75°C Wire Size - AWG Max. O.C.P. Amps/Type Circuit Circuit Circuit Heater Models Models 208/230 208/230 208/230 208/230 208/230 208/230 6HK16501306 37.5/41.3 20.3/22.4 40/45 25/25 12/12 AHR24B3XH21...
  • Page 8: Typical Applications

    680206-YTG-C-0612 Electrical Data - (For Single Source Power Supply) - Copper Wire - 208/230-3-60 Field Wiring Heater Heat Kit - Models Amps Min. Circuit Ampacity 75°C Wire Size - AWG Max. O.C.P. Amps/Type Three Phase 240V 208V 230V 208V 230V 208V 230V AHR24B3XH21...
  • Page 9 680206-YTG-C-0612 TYPICAL THERMOSTAT CONNECTIONS Johnson Controls Unitary Products...
  • Page 10 3. For optimal performance static pressures of 0.2 to 0.5 are recommended. Operation not recommended in shaded areas. Subject to change without notice. Published in U.S.A. 680206-YTG-C-0612 Copyright © 2012 by Johnson Controls, Inc. All rights reserved. Supersedes: 680206-YTG-B-0311 York International Corp. 5005 York Drive Norman, OK 73069...