York 12 SEER H*RC018 THRU 060 Technical Manual

York 12 SEER H*RC018 THRU 060 Technical Manual

Split-system air conditioner 12 seer

Advertisement

TECHNICAL GUIDE
SPLIT-SYSTEM
AIR CONDITIONERS
12 SEER
MODELS:
H*RC018 THRU 060
(1.5 THRU 5 NOMINAL TONS, 1 PH)
H*RC036S(25,46) THRU 060
(3 THRU 5 NOMINAL TONS, 3 PH)
R
P
CERTIFICATION APPLIES ONLY
WHEN THE COMPLETE
SYSTEM IS LISTED
WITH ARI.
LISTED
Due to continuous product improvement, specifications
are subject to change without notice.
Visit us on the web at www.york.com for the most
up-to-date technical information.
Additional rating information can be found at
www.ariprimenet.org.
FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE
ISO 9001
Certified Quality
Management System
DESCRIPTION
The 12 SEER Series condensing unit is the outdoor part of a
versatile system of air conditioning. It is designed to be cus-
tom-matched with one of UPG's complete line of evaporator
sections, each designed to serve a specific function. Match-
ing Air Handlers are available for upflow, downflow or hori-
zontal applications to provide a complete system. Electric
Heaters are available if required. Add-On coils are available
for use with upflow, downflow or horizontal furnaces and air
handlers.
WARRANTY
Single Phase Units:
5-year limited parts warranty.
10-year limited compressor warranty.
Three Phase Units:
1-year limited parts warranty.
5-year limited compressor warranty.
FEATURES
• QUALITY CONDENSER COILS - The coil is constructed
of enhanced copper tube and aluminum fins.
• COIL PROTECTION - Coils are protected from damage by
a polymer mesh applied between the coil face, and a PVC
coated steel coil guard.
• PROTECTED COMPRESSOR - The compressor is inter-
nally protected against high pressure and temperature.
This is accomplished by the simultaneous operation of
high pressure relief valve and a temperature sensor which
protects the compressor if undesirable operating condi-
tions occur. A liquid line filter-drier further protects the
compressor.
• DURABLE FINISH - The cabinet is made of pre-painted
steel. The pre-treated galvanized steel provides a better
paint to steel bond, which resists corrosion and rust creep.
Special primer formulas and matted textured champagne
finish insure less fading when exposed to sunlight.
• LOWER INSTALLED COST - Installation time and costs
are reduced by easy power and control wiring connec-
tions. Discharge line heat exchanger knockouts are pro-
vided, if required. Available in sweat connect models only.
The unit contains enough refrigerant for matching indoor
coils and 15 feet of interconnecting piping. The small base
dimension means less space is required on the ground or
roof.
• TOP DISCHARGE - The warm air from the top mounted
fan is blown up away from the structure and any landscap-
ing. This allows compact location on multi-unit applica-
tions.
• LOW OPERATING SOUND LEVEL - The upward air flow
carries the normal operating noise up away from the living
area. The rigid top panel effectively isolates any motor
sound. Isolator mounted compressor and the rippled fins
of the condenser coil muffle the normal fan motor and
compressor operating sounds.
• LOW MAINTENANCE - Long life permanently lubricated
motor-bearings need no annual servicing.
• EASY SERVICE ACCESS - Fully exposed refrigerant con-
nections, a single panel covering the electrical controls
and the molex plug in the control box connecting the con-
denser fan, make for easy servicing of the unit.
• SECURED SERVICE VALVES - Secured re-usable ser-
vice valves are provided on both the liquid and vapor
sweat connections for ease of evacuating and charging.
• U.L. and C.U.L. listed - approved for outdoor application.
Certified in accordance with the Unitary Small Equipment cer-
tification program, which is based on ARI Standard 210/240.
036-21137-004 Rev. C (0505)

Advertisement

Table of Contents
loading

Summary of Contents for York 12 SEER H*RC018 THRU 060

  • Page 1 Certified Quality Management System Due to continuous product improvement, specifications are subject to change without notice. Visit us on the web at www.york.com for the most up-to-date technical information. Additional rating information can be found at www.ariprimenet.org. FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE 036-21137-004 Rev.
  • Page 2 036-21137-004 Rev. C (0505) Physical and Electrical Data - 1 Phase MODEL H2RC018S06 H2RC024S06 H2RC030S06 H2RC036S06 H2RC042S06 H2RC048S06 H4RC060S06 Unit Supply Voltage Normal Voltage Range 10.1 Minimum Circuit Ampacity Max. Overcurrent Device Amps Recip Compressor Type Rated Load Compressor Amps Locked Rotor Crankcase Heater Fan Motor Amps...
  • Page 3 Additional R-22 Charge / Orifice Size for Various Matched Systems - 1 Phase Outdoor Unit H2RC018S06 H2RC024S06 H2RC030S06 H2RC036S06 H2RC042S06 H2RC048S06 H4RC060S06 Unit Orifice (s) Factory R-22 Charge, lbs-oz. Indoor Coil Coil Orifice G2FD024(S,H)14,17 G2FD030(S,H)17 G2FD035(S,H)14 G2FD036(S,H)17 G2FD036(S,H)21 G2FD042(S,H)21 G2FD046(S,H)17 G2FD048(S,H)21,24 G2FD060(S,H)24 G2FD061H24...
  • Page 4 036-21137-004 Rev. C (0505) Additional R-22 Charge / Orifice Size for Various Matched Systems (Continued)- 1 Phase Outdoor Unit H2RC018S06 H2RC024S06 H2RC030S06 H2RC036S06 H2RC042S06 H2RC048S06 H4RC060S06 Unit Orifice (s) Factory R-22 Charge, lbs-oz. Indoor Coil Coil Orifice G1NA036S17L G1NA048S21D G1NA048S24P G1NA060S24T G1NF024SOF G1NF036SOF...
  • Page 5 Additional R-22 Charge / Orifice Size for Various Matched Systems - 3 Phase Outdoor Unit Unit Orifice (s) Factory R-22 Charge, lbs-oz Indoor Coil Coil Orifice G2FD035(S,H)14 G2FD036(S,H)17,21 G2FD042(S,H)21 G2FD046(S,H)17 G2FD048(S,H)21,24 G2FD060(S,H)24 G2FD061H24 G1FA/G1UA036S14 G1FA/G1UA036S17,21 G1FA/G1UA048S17 G1FA/G1UA048S21 G1FA/G1UA060S21,24 G1NA036S17L G1NA048S21D G1NA048S24P G1NA060S24T G1NF036SOF...
  • Page 6: Table Of Contents

    036-21137-004 Rev. C (0505) COOLING CAPACITY - With Air Handler Coils AIR HANDLER UNIT MODEL ELECTRIC MODEL HEAT KW H2RC018S06 N1AHB0806 2,5,8,10 N1AHB0806 2,5,8,10 H2RC024S06 N1AHB0806 2,5,8,10 N1AHB1206 2,5,8,10 H2RC030S06 N1AHB1206 2,5,8,10 N1AHB1206 5,8,10,15,19 H2RC036S06 N1AHB1206 5,8,10,15,19 N1AHC1606 5,8,10,15,20 H2RC042S06 N1AHC1606 5,8,10,15,20 N1AHC1606...
  • Page 7: G2Fd024(S,H)17 600

    COOLING CAPACITY - Upflow, Downflow & Horizontal Furnaces and Coils FURNACE** UNIT MODEL CFM RANGE (Min.-max.) 14,17 H2RC018S06 14,17 14,17 G2FD024(S,H)14,17 14,17 17,21 H2RC024S06 14,17 17,21 14,17 G2FD024(S,H)14,17 17,21 H2RC030S06 1125 17,21 For Notes See Page 9. Unitary Products Group COIL NET MBH MODEL...
  • Page 8: G2Fd036(S,H)17 1200

    036-21137-004 Rev. C (0505) COOLING CAPACITY - Upflow, Downflow & Horizontal Furnaces and Coils (Continued) FURNACE** UNIT MODEL CFM RANGE (Min.-max.) 17,21 1050 H2RC036S06 1350 17,21 21,24 G2FD048(S,H)21,24 17,21 1050 H1RC036S(25,46) 1350 17,21 21,24 G2FD048(S,H)21,24 21,24 1225 H2RC042S06 1575 21,24 21,24 G2FD048(S,H)21,24 For Notes See Page 9.
  • Page 9: G2Fd048(S,H)21 1575

    COOLING CAPACITY - Upflow, Downflow & Horizontal Furnaces and Coils (Continued) FURNACE** UNIT MODEL CFM RANGE (Min.-max.) 21,24 1375 H2RC048S06 1775 21,24 21,24 G2FD048(S,H)21,24 21,24 1400 H1RC048S(25,46) 1800 21,24 21,24 G2FD048(S,H)21,24 1600 H4RC060S06 2200 21,24 1600 H2RC060S(25,46) 2200 21,24 1. TXV = Use 1TV700 Series Kit. *Requires 2FD Blower Time Delay unless a standard furnace is equipped with one.
  • Page 10: G2Fd024(S,H)14

    036-21137-004 Rev. C (0505) COOLING CAPACITY - With Variable Speed Furnaces VARIABLE SPEED UNIT MODEL FURNACE MODEL P1DUA12V/PV8A12****UH P1DUA12V/PV8A12****UH H2RC018S06 P1XDB12V P1XUB12V P1XUB12V P1DUA12V/PV8A12****UH P1DUA12V/PV8A12****UH H2RC024S06 P1XDB12V P1XUB12V P1XUB12V P1DUA12V/PV8A12****UH P1DUA12V/PV8A12****UH P1DUB16V/PV8B16****UH P1DUB16V/PV8B16****UH H2RC030S06 P1XDB12V P1XUB12V P1XUB12V P1XUC16V P1XUC16V P1DUA12V/PV8A12****UH P1DUA12V/PV8A12****UH P1DUB16V P1DUB16V...
  • Page 11 COOLING CAPACITY - With Variable Speed Furnaces VARIABLE SPEED UNIT MODEL FURNACE MODEL P1DUC20V/PV8C20****UH P1DUC20V/PV8C20****UH P1XDD20V P1XUC16V P1XUC16V H2RC048S06 P1XUC20V P1XUC20V P1XUD20V P1XUD20V P1XUD20V P1DUC20V/PV8C20****UH P1DUC20V/PV8C20****UH P1XUC16V P1XUC16V H1RC048S(25,46) P1XUC20V P1XUC20V P1XUD20V P1XUD20V P1XUD20V P*DUC20V P*DUC20V P*DUC20V P1XUC20V P1XUC20V P1XUC20V P1XUD20V P1XUD20V P1XUD20V...
  • Page 12 036-21137-004 Rev. C (0505) All dimensions are in inches. They are subject to change without notice. Certified dimensions will be provided upon request. DIMENSIONS - 1 Phase Unit Dimensions Refrigerant Connection Model (Inches) Liquid 3/8” 1. Including Fan Guard. Expander fitting required for 1-1/8” line set. DIMENSIONS - 3 Phase Unit Dimensions...
  • Page 13 TYPICAL INSTALLATION 60” OVERHEAD CLEARANCE 10” CLEARANCE COIL AREA NOTE: ALL OUTDOOR WIRING MUST BE WEATHERPROOF. TYPICAL FIELD WIRING - 1 Phase Application ALL FIELD WIRING TO BE IN ACCORDANCE WITH ELECTRIC CODE (NEC) AND/OR LOCAL CODES POWER WIRING 208/230-1-60 CONTACTOR TERMINALS GND.
  • Page 14 036-21137-004 Rev. C (0505) COOLING PERFORMANCE DATA AIR CONDITIONER MODEL NO. INDOOR COIL MODEL NO. IDCFM CONDENSING| ENTERING AIR ID DB (°F) TEMPERATURE ID WB (°F) T.C. S.C. T.C. S.C. T.C. S.C. T.C. S.C. T.C. S.C. T.C. S.C. NOTE: ALL CAPACITIES ARE NET WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM. Multipliers for determining the performance with other indoor sections.
  • Page 15 COOLING PERFORMANCE DATA AIR CONDITIONER MODEL NO. INDOOR COIL MODEL NO. IDCFM CONDENSING ENTERING AIR ID DB (°F) TEMPERATURE ID WB (°F) T.C. S.C. T.C. S.C. T.C. S.C. T.C. S.C. T.C. S.C. T.C. S.C. NOTE: ALL CAPACITIES ARE NET WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM. Multipliers for determining the performance with other indoor sections.
  • Page 16: G2Fd046(S,H)17

    036-21137-004 Rev. C (0505) COOLING PERFORMANCE DATA AIR CONDITIONER MODEL NO. INDOOR COIL MODEL NO. IDCFM CONDENSING ENTERING AIR ID DB (°F) TEMPERATURE ID WB (°F) T.C. S.C. T.C. S.C. T.C. S.C. T.C. S.C. T.C. S.C. T.C. S.C. NOTE: ALL CAPACITIES ARE NET WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM. Multipliers for determining the performance with other indoor sections.
  • Page 17: G2Fd046(S,H)17

    COOLING PERFORMANCE DATA AIR CONDITIONER MODEL NO. INDOOR COIL MODEL NO. IDCFM CONDENSING ENTERING AIR ID DB (°F) TEMPERATURE ID WB (°F) T.C. S.C. T.C. S.C. T.C. S.C. T.C. S.C. T.C. S.C. T.C. S.C. NOTE: ALL CAPACITIES ARE NET WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM. Multipliers for determining the performance with other indoor sections.
  • Page 18 036-21137-004 Rev. C (0505) COOLING PERFORMANCE DATA AIR CONDITIONER MODEL NO. INDOOR COIL MODEL NO. IDCFM CONDENSING ENTERING AIR ID DB (°F) TEMPERATURE ID WB (°F) T.C. S.C. T.C. S.C. T.C. S.C. T.C. S.C. T.C. S.C. T.C. S.C. NOTE: ALL CAPACITIES ARE NET WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM. Multipliers for determining the performance with other indoor sections.
  • Page 19 COOLING PERFORMANCE DATA AIR CONDITIONER MODEL NO. INDOOR COIL MODEL NO. IDCFM CONDENSING ENTERING AIR ID DB (°F) TEMPERATURE ID WB (°F) T.C. S.C. T.C. S.C. T.C. S.C. T.C. S.C. T.C. S.C. T.C. S.C. NOTE: ALL CAPACITIES ARE NET WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM. Multipliers for determining the performance with other indoor sections.
  • Page 20 036-21137-004 Rev. C (0505) COOLING PERFORMANCE DATA AIR CONDITIONER MODEL NO. INDOOR COIL MODEL NO. IDCFM CONDENSING ENTERING AIR ID DB (°F) TEMPERATURE ID WB (°F) T.C. S.C. T.C. S.C. T.C. S.C. T.C. S.C. T.C. S.C. T.C. S.C. NOTE: ALL CAPACITIES ARE NET WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM. Multipliers for determining the performance with other indoor sections.
  • Page 21 COOLING PERFORMANCE DATA AIR CONDITIONER MODEL NO. INDOOR COIL MODEL NO. IDCFM CONDENSING ENTERING AIR ID DB (°F) TEMPERATURE ID WB (°F) T.C. S.C. T.C. S.C. T.C. S.C. T.C. S.C. T.C. S.C. T.C. S.C. NOTE: ALL CAPACITIES ARE NET WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM. Multipliers for determining the performance with other indoor sections.
  • Page 22 036-21137-004 Rev. C (0505) COOLING PERFORMANCE DATA AIR CONDITIONER MODEL NO. INDOOR COIL MODEL NO. IDCFM CONDENSING ENTERING AIR ID DB (°F) TEMPERATURE ID WB (°F) T.C. S.C. T.C. S.C. T.C. S.C. T.C. S.C. T.C. S.C. T.C. S.C. NOTE: ALL CAPACITIES ARE NET WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM. Multipliers for determining the performance with other indoor sections.
  • Page 23 COOLING PERFORMANCE DATA AIR CONDITIONER MODEL NO. INDOOR COIL MODEL NO. IDCFM CONDENSING ENTERING AIR ID DB (°F) TEMPERATURE ID WB (°F) T.C. S.C. T.C. S.C. T.C. S.C. T.C. S.C. T.C. S.C. T.C. S.C. NOTE: ALL CAPACITIES ARE NET WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM. Multipliers for determining the performance with other indoor sections.
  • Page 24 AIR HANDLERS - FOR NON-FURNACE APPLICATIONS N1AH OR N1VS MODULAR BLOWER (UPFLOW, HORIZONTAL AND DOWNFLOW) Subject to change without notice. Printed in U.S.A. Copyright © by York International Corp. 2005. All rights reserved. Unitary Products Group G1HD HORIZONTAL DUCT G2FD*...

Table of Contents