TECHNICAL GUIDE
STELLAR 2000
TM
SPLIT-SYSTEM AIR CONDITIONERS
10 SEER
MODELS: H*DB018 THRU 060
(1 THRU 5 NOMINAL TONS, 1 PH)
H*DB036 THRU 076
(3 THRU 6-1/3 NOMINAL TONS, 3 PH)
This product was manufactured
Certification applies only
in a plant whose quality system
when the complete
is certified/registered as being
system is listed
in conformity with ISO 9001.
Due to continuous product improvement, specifications
are subject to change without notice.
Visit us on the web at www.york.com for the most
up-to-date technical information.
Additional rating information can be found at
www.ariprimenet.org.
FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE
Models 018-048
Model 060
R
P
LISTED
with ARI.

DESCRIPTION

®
The HDB Series condensing unit is the outdoor part of a ver-
satile system of air conditioning. It is designed to be custom-
matched with one of YORK's complete line of evaporator sec-
tions, each designed to serve a specific function. Matching
Air Handlers are available for upflow, downflow or horizontal
application to provide a complete system. Electric heaters are
available if required. Add-On coils are available for use with
upflow, downflow or horizontal furnaces.
WARRANTY
Single Phase Units:
5-year limited parts warranty.
5-year limited compressor warranty.
Three Phase Units:
1-year limited parts warranty.
5-year limited compressor warranty.

FEATURES

• QUALITY CONDENSER COILS - The coil is constructed
of enhanced copper tube and aluminum fins.
• COIL PROTECTION - Coils are protected from damage by
a polymer mesh applied between the coil face, and a PVC
coated steel coil guard.
• PROTECTED COMPRESSOR - The compressor is inter-
nally protected against high pressure and temperature.
This is accomplished by the simultaneous operation of
high pressure relief valve and a temperature sensor which
protects the compressor if undesirable operating condi-
tions occur. A liquid line filter-drier further protects the
compressor.
• DURABLE FINISH - Cabinet is made of powder painted
steel over pre-primered steel. The pre-treated galvanized
steel provides a better paint to steel bond, which resists
corrosion and rust creep. Special primer formulas and
automotive quality finish insure less fading when exposed
to sunlight.
• LOWER INSTALLED COST - Installation time and costs
are reduced by easy power and control wiring connec-
tions. Discharge line heat exchanger knockouts are pro-
vided, if required. Both quick connect and sweat connect
models are available. Both service valves are firmly affixed
to the unit. The sweat unit contains enough refrigerant for
matching indoor coils and 15 feet of interconnecting pip-
ing. The small base dimension means less space is
required on the ground or roof.
• TOP DISCHARGE - The warm air from the top mounted
fan is blown up away from the structure and any landscap-
ing. This allows compact location on multi-unit applica-
tions.
• LOW OPERATING SOUND LEVEL - The upward air flow
carries the normal operating noise up away from the living
area. The rigid top panel effectively isolates any motor
sound. Isolator mounted compressor and the rippled fins
of the condenser coil muffle the normal fan motor and
compressor operating sounds.
• LOW MAINTENANCE - Long life permanently lubricated
motor- bearings need no annual servicing.
• EASY SERVICE ACCESS -
connections, a single panel covering the electrical con-
trols, and the molex plug in the control box connecting the
condenser fan make for easy servicing of the unit.
• SECURED SERVICE VALVES - Secured re-usable ser-
vice valves are provided on both the liquid and vapor
sweat connections for ease of evacuating and charging.
• U.L. and C.U.L. listed - approved for outdoor application.
Certified in accordance with the Unitary Small Equipment cer-
tification program, which is based on ARI Standard 210/240.
036-21024-006 Rev. D (0403)
Fully exposed refrigerant

Advertisement

Table of Contents
loading

Summary of Contents for York H4DB018

  • Page 1 The HDB Series condensing unit is the outdoor part of a ver- satile system of air conditioning. It is designed to be custom- matched with one of YORK's complete line of evaporator sec- tions, each designed to serve a specific function. Matching Air Handlers are available for upflow, downflow or horizontal application to provide a complete system.
  • Page 2 036-21024-006 Rev. D (0403) Physical and Electrical Data - 1 Phase MODEL H4DB018 H4DB024 H4DB030 H4DB036 H5DB042 H5DB048 H4DB060 Unit Supply Voltage 208/230-1-60 187 to 252 Normal Voltage Range Minimum Circuit Ampacity 13.0 15.2 16.9 23.0 27.2 31.9 37.6 Max. Overcurrent Device Amps...
  • Page 3 036-21024-006 Rev. D (0403) Additional R-22 Charge / Orifice Size for Various Matched Systems - 1 Phase OUTDOOR UNITS H4DB018 H4DB024 H4DB030 H4DB036 H4DB042 H5DB048 H4DB060 UNIT ORIFICE(S) 53, 55 59, 61 65, 67, 69 73, 75 73,78,81 81, 84 87, 90, 93 FACTORY CHARGE, LBS.
  • Page 4 036-21024-006 Rev. D (0403) Additional R-22 Charge / Orifice Size for Various Matched Systems - 3 Phase OUTDOOR UNITS H*DB036 H*DB048 H*DB060 H*DB076 UNIT ORIFICE(S) 73, 75 81,84 90, 93 FACTORY CHARGE, LBS. - OZ. 4 - 9 6 -0 8 - 0 14-0 INDOOR COIL...
  • Page 5 NET MBH SEER RATED SEER ELECTRIC MODEL MODEL MODEL W/O TXV HEAT. KW + TXV TOTAL SENS. 1 PH 10 SEER AC WITH N1AH / G2FD H4DB018 N1AHB0806 2,5,8,10 G2FD024(S,H)17 18.8 13.9 10.30 9.25 N1AHB0806 2,5,8,10 G2FD024(S,H)17 24.8 18.4 10.50 9.75...
  • Page 6 56.5 39.5 10.00 9.40 H4DB076 K2EU090 10,16,25,36 2550 76.6 53.6 10.30 1 PH 10 SEER AC / M1HC H4DB018 M1HC018F01 16.8 12.4 10.30 9.60 H4DB024 M1HC024F01 24.2 17.9 11.00 11.10 Rated in accordance with DOE test procedures (Federal Register 12-27-79 and 3-18-88) and ARI Standards 210.
  • Page 7 G1FA024S14,17 18.4 13.6 10.15 9.10 G1FA030S14 18.8 13.9 10.30 9.25 G1HD024 18.9 14.0 10.30 9.30 G1NA030S17H 19.0 14.1 10.50 9.35 H4DB018 14,17 G1UA024S14,17 18.4 13.6 10.15 9.10 G1UA030S14 18.8 13.9 10.30 9.25 14,17 G2FD024(S,H)14,17 18.8 13.9 10.30 9.25 G2FD030(S,H)17 19.0 14.1...
  • Page 8 036-21024-006 Rev. D (0403) COOLING CAPACITY - With Upflow, Downflow and Horizontal Furnace and Coils (Continued) FURNACE** COOLING UNIT COIL NET MBH CFM RANGE RATED SEER W/O TDR SEER + TDR MODEL MODEL (MIN.-MAX.) W/O TXV W/O TXV TOTAL SENS. G1FA036S14 1200 35.0...
  • Page 9: Cooling Performance

    41.4 3.09 31.1 4.01 21.7 5.31 68.5 19.3 1.43 16.5 1.58 13.7 1.74 68.5 45.2 3.15 34.2 4.09 24.0 5.39 H4DB018 H5DB042 76.0 21.4 1.48 18.4 1.65 15.4 1.83 76.0 49.2 3.23 37.3 4.18 26.4 5.48 84.0 23.5 1.53 20.4 1.73...
  • Page 10 036-21024-006 Rev. D (0403) TYPICAL FIELD WIRING - 1 PHASE APPLICATION ALL FIELD WIRING TO BE IN ACCORDANCE WITH ELECTRIC CODE (NEC) AND/OR LOCAL CODES POWER WIRING POWER WIRING 208/230-1-60 24 VOLT CONTROL WIRING CONTROL WIRING 230-1-50 MINIMUM 18 GA. WIRE FACTORY WIRING (NEC CLASS 2) FURNACE OR AIR HANDLER TERMINAL BLOCK...
  • Page 11 036-21024-006 Rev. D (0403) ACCESSORIES 48" OVERHEAD CLEARANCE Refer to Price Manual for specific model numbers. Hard Start Kit - Provides increased starting torque for areas with low voltage. Compressor Blanket - Designed to further reduce the nor- mal compressor operating sound. Refer to price pages for AIR IN 4 SIDES specific match-ups.
  • Page 12 036-21024-006 Rev. D (0403) COOLING PERFORMANCE DATA AIR CONDITIONER MODEL NO. H4DB018 INDOOR COIL MODEL NO. G1FA024S14,17 ID CFM CONDENSER ENTERING AIR ID DB (°F) TEMPERATURE ID WB (°F) T.C. 22.1 20.3 18.5 16.8 22.4 20.6 18.8 17.1 22.6 20.8 19.0...
  • Page 13 036-21024-006 Rev. D (0403) COOLING PERFORMANCE DATA AIR CONDITIONER MODEL NO. H4DB024 INDOOR COIL MODEL NO. G1FA024S14,17 ID CFM CONDENSER ENTERING AIR ID DB (°F) TEMPERATURE ID WB (°F) T.C. 28.1 25.7 23.4 21.2 28.3 25.9 23.6 21.4 28.5 26.1 23.8 21.5 S.C.
  • Page 14 036-21024-006 Rev. D (0403) COOLING PERFORMANCE DATA AIR CONDITIONER MODEL NO. H4DB030 INDOOR COIL MODEL NO. G1FA036S17,21, G2FD030(S,H)17 ID CFM 1000 1100 CONDENSER ENTERING AIR ID DB (°F) TEMPERATURE ID WB (°F) T.C. 33.5 30.7 27.9 25.3 34.1 31.3 28.4 25.8 34.6 31.7...
  • Page 15 036-21024-006 Rev. D (0403) COOLING PERFORMANCE DATA AIR CONDITIONER MODEL NO. H4DB036 INDOOR COIL MODEL NO. G1FA036S17,21 ID CFM 1100 1200 1300 CONDENSER ENTERING AIR ID DB (°F) TEMPERATURE ID WB (°F) T.C. 41.4 37.9 34.5 31.3 41.9 38.4 35.0 31.8 42.3 38.8...
  • Page 16 036-21024-006 Rev. D (0403) COOLING PERFORMANCE DATA AIR CONDITIONER MODEL NO. H5DB042 INDOOR COIL MODEL NO. G1FA048S21 ID CFM 1300 1400 1500 CONDENSER ENTERING AIR ID DB (°F) TEMPERATURE ID WB (°F) T.C. 48.0 44.1 40.1 36.5 48.4 44.5 40.5 36.9 48.8 44.8...
  • Page 17 036-21024-006 Rev. D (0403) COOLING PERFORMANCE DATA AIR CONDITIONER MODEL NO. H5DB048 INDOOR COIL MODEL NO. G1FA048S21 ID CFM 1550 1600 1650 CONDENSER ENTERING AIR ID DB (°F) TEMPERATURE ID WB (°F) T.C. 53.0 49.0 45.0 41.2 53.2 49.2 45.2 41.4 53.4 49.3...
  • Page 18 036-21024-006 Rev. D (0403) COOLING PERFORMANCE DATA AIR CONDITIONER MODEL NO. H4DB060 INDOOR COIL MODEL NO. G1FA060S21,24 ID CFM 1700 1850 2000 CONDENSER ENTERING AIR ID DB (°F) TEMPERATURE ID WB (°F) T.C. 33.7 58.8 53.8 49.2 64.3 59.3 54.4 49.7 64.8 59.8...
  • Page 19 036-21024-006 Rev. D (0403) COOLING PERFORMANCE DATA AIR CONDITIONER MODEL NO. H4DB076 INDOOR COIL MODEL NO. KEU090A33A ID CFM 1900 2550 3150 CONDENSER ENTERING AIR ID DB (°F) TEMPERATURE ID WB (°F) T.C. 75.4 72.8 70.5 78.2 75.5 73.4 81.0 78.2 76.2 S.C.
  • Page 20 F3RP / F3FP/ F2FV COIL FAN COIL UNITS (UPFLOW, HORIZONTAL) Subject to change without notice. Printed in U.S.A. 036-21024-006 Rev. D (0403) Copyright © by York International Corp. 2003. All rights reserved. Supersedes: 036-21024-006 Rev C (0203) Unitary 5005 Norman Product...

Table of Contents