22
£ng/ish
l/ertica/ batch freezer
8.3
Yearly maintenance
Periodically (basing yourself on the environnnental conditions in which the device operates) and in any case once every
year, make sure to have a general checkup.
A
THE CHECK-UP MUST BE MADE BY THE AUTHORISED ASSISTANCE SERVICE, OR, IN ANY CASE, BY
TECHNICALLY AUTHORISED PERSONNEL WITH ADEQUATE TOOL. THE MAINTENANCE OPERATIONS
RESERVED TO THE SERVICE ASSISTANCE CAN BE DANGEROUS IF CARRIED OUT BY NON-PROFES-
SIONALS, THEREFORE, FOR HIS OWN SAFETY, THE USER MUST NEVER CARRY THEM OUT.
9
PERIODS OF INACTIVITY
If long periods of inactivity are foreseen, proceed as follows:
wash up completely the device (see Section 7);
switch off the power breaker and unplug the device;
devices with WATER condensation: close the water faucet and relieve pressure from inside the delivery pipe by
unscrewing one of the pipe fittings. Remove both delivery and drain pipes and let all water out. Before using the pipes
again, following a long period of inactivity, check for any damages or cracks and replace, if necessary, pipe fittings'
gaskets.
if the device will be stored in a different place, group all the documentation, together with the present manual, and
enclose it at the device (i.e. in the cylinder).
Before storing machine (supplied with water condensation) at temperature lower than 0°C it is ABSO-
LUTELY necessary to release all water from condenser and from feed and drain pipes, failure to do so will
cause water to freeze and SERIOUSLY DAMAGE refrigerating system. Call Assistance Service.
10
MALFUNCTIONS
Y J ^
WE RECOMMEND YOU TO CALL IMMEDIATELY THE ASSISTANCE SERVICE IF A MALFUNCTION DIFFER-
ENT FROM THOSE HERE DESCRIBED IS FOUND.
Note:
the following malfunctions do not refer to problems noticed in the installation phase, but ONLY on correctly
installed - and already functioning - devices.
THE DEVICE DOES NOT WORK OR STOPS WORKING.
With the Main Breaker on 1 the POWER indicator [Z1] DOES NOT TURN ON.
Cause:
A
The plug is not correctly plugged.
The plug is defective. A qualified technician should substitute it.
Power in the socket is missing. Check that the breakers, the omnipolar switches and the
differentials (lifesavers) on the electric plant are closed. If they aren't, before closing them,
make sure that no one is making electrical maintenance.
A protective fuse of the electric plant is blown. Find and eliminate the eventual cause of
overload. Substitute blown fuses with others of the same kind.
The supply cable is defective. BEFORE, cut down electrical feeding at the socket by opening
the breaker above it, then disconnect the plug and call the Assistance Service.
DO NOT TOUCH THE DAMAGED ELECTRICAL CABLES BEFORE HAVING CUT DOWN
THE ELECTRICAL SUPPLY!
With the Main Breaker on 1 the POWER indicator [Z1] TURNS ON, but the display shows 2 small squares
and the device does not work.
Cause:
The lid is not correctly closed or tends to open;
English
Operating instructions
4.2
Unpacking
WOOD PACKING: unnail the top panel, then separate the lateral panels.
CARDBOARD PACKING; cut the strips and remove the cardboard from the top;
After having opened the packing, make sure the device isn't damaged. In case of doubt, do not use it, and call the Seller.
A
| \
THE OPENING OF THE LATERAL PANEL IS ONLY ALLOWED TO THE ASSISTANCE SERVICE OR TO
QUALIFIED TECHNICIANS AND MUST BE MADE BEFORE CONNECTING IT MAKE SURE NOT TO DAM-
AGE THE INTERNAL PARTS OF THE DEVICE.
Remove both the lateral panels unscrewing the relevant fixing screws [21];
Find and unscrew the bolts [22] which fix the device's frame at the packing's basement;
©
The outlet of the supply cable is placed on the device's lower side. During the lifting make sure not to
damage it.
Lift the device from the basement, possibly working on the lower side, near the wheels, and however, only on the
frame's carrying parts. Remove the basement, and lean the device on the floor avoiding bumps;
®
D 0 NOT insert objects, ropes or brackets for the lifting THROUGH the device, since these could damage
the inside parts.
Re-close the lateral panels;
Replace or move the packing, which is produced with entirely recyclable materials
INSTALLATION
A
THE INSTALLATION MUST BE CARRIED OUT ONLY BY THE ASSISTANCE SERVICE OR BY TECHNI-
CALLY AUTHORISED PERSONNEL AND IN COMPLIANCE WITH THE LAWS IN FORCE, ALWAYS FOL-
LOWING INSTRUCTIONS OF THE MANUFACTURER.
5.1
Placing and check of the parts
Place the device on the floor, on a flat and steady surface.
Install the device away from any source of heat, avoiding a direct exposition to sun
radiation and making sure that air can freely circulate around each side of the device
itself.
®
The devices with AIR CONDENSING need at least a 50 cm free space in
front of the condenser's grill, to assure the refrigerating plant correct
functioning. Further information are reported on the Technical Book
(Technical Data section).