Summary of Contents for Ivoclar Vivadent SR Ivocap

  • Page 1 SR Ivocap Equipment System ® Operating Instructions...
  • Page 3 Index Page Views of the Furnace, List of Parts Introduction / Signs and Symbols Introduction Signs and symbols Notes regarding the Operating Instructions Safety First Indications Product Description Components Hazardous areas and safety equipment Functional description Accessories Installation Unpacking and checking the contents Selecting the location Operation Operating elements at the pressure apparatus...
  • Page 4 Views of the Equipment System, List of Parts A) Pressure apparatus D) Capsule plunger "ID3" E) Investment aid A1 = Locking valve A2 = Manometer F) Funnel A3 = Extrusion piston A4 = Vise shank G) Timer A5 = Safety loop B) Clamping frame “JS3”...
  • Page 5: Introduction / Signs And Symbols

    1. Introduction / Signs and Symbols 1.1 Introduction 1.2 Signs and symbols 1.3 Notes regarding the Operating The SR Ivocap System is an The signs and symbols in Instructions injection technique which these Operating Instructions has been especially facilitate the finding of...
  • Page 6: Safety First

    Further instructions to assure personnel who work with the proper use of the system: SR Ivocap System or who have to carry out The SR Ivocap System must only be used for – The instructions, injecting the SR Ivocap material and it should maintenance or repair work.
  • Page 7: Product Description

    (various manufacturers) • Plastic floaters (Ivoclar Vivadent) 3.3 Functional description 3.4 Accessories The SR Ivocap System is an injection • Cap Vibrator (Ivoclar Vivadent) technique which has been especially • Wall bracket for 4 pressure apparatus developed to compensate curing (e.g.
  • Page 8: Installation

    (see delivery form in Chapter 9) and qualified technicians (electricians, plumbers). transportation damage. If certain parts are damaged or missing, contact your local Ivoclar Vivadent Customer Service. We Furthermore, the national installation recommend keeping the original packaging requirements of the corresponding for future transportation purposes.
  • Page 9: Operation

    5. Operation 5.2 Operating elements on the 5.1 Operating elements on the pressure apparatus clamping frame Safety loop (A5) Compressed air locking valve (A1) Thrust collar with lever (B2) The safety loop is used to secure the This locking valve is used to close or vise shanks.
  • Page 10: Practical Use

    20 minutes thereof Compressed air 6 bar Capsule Flask Water level Mark for water level Flowing cold water For information on how to process the material please refer to the material Instructions for Use of the SR Ivocap System.
  • Page 11: Maintenance, Cleaning, And Diagnosis

    The time for these maintenance procedures be performed by qualified service personnel depends on the frequency of use and work- at a certified Ivoclar Vivadent Service Center. ing habits of the users. For that reason, the recommended times are only approximates.
  • Page 12: Error Messages

    The rod of the injection plunger cannot be moved, even if the connection to the compressed from moving, open valve air source is interrupted. It seems to be stuck. Injection plunger does not move. The SR Ivocap material is not injected. – No compressed air present – Capsule cover was not removed –...
  • Page 13: Product Specifications

    9. Product Specifications This chapter contains all relevant 9.2 Technical data 9.3 Acceptable operating product specifications. conditions Weight: Flask 1.3 kg Acceptable humidity range 9.1 Delivery form Clamping frame ID3 2.3 kg Maximum relative humidity at 31 °C Pressure apparatus 2.0 kg (87 °F) gradually decreasing to 50% at 1 Pressure apparatus...
  • Page 16 Tel. +86 21 5456 0776 Ivoclar Vivadent Pty. Ltd. Fax. +86 21 6445 1561 Ivoclar Vivadent S.A. de C.V. Ivoclar Vivadent UK Limited 1 – 5 Overseas Drive www.ivoclarvivadent.com Av. Mazatlán No. 61, Piso 2 Ground Floor Compass Building P.O.