Mitsubishi Electric MR-J2S-*B Series Instruction Manual page 98

General-purpose ac servo. sscnet compatible. servo amplifier
Table of Contents

Advertisement

5. PARAMETERS
Classifi-
No.
Symbol
cation
60
*OPC
Optional function C
Used to select the encoder output pulse direction.
61
NH2
Machin resonance suppression filter 2
Used to selection the machine resonance suppression filter 2. (Refer
to Section 7.2.)
Name and Function
0
0
0
Encoder pulse output phase changing
Changes the phases of A, B-phase encoder pulses output .
Set value
A phase
0
B phase
A phase
1
B phase
0
Notch frequency selection
Set "00" when you have set adaptive vibration
suppression control to be "valid" or "held"
(parameter No. 25:
Setting Frequency
Setting
00
Invalid
08
01
4500
09
02
2250
0A
03
1500
0B
04
1125
0C
05
900
0D
750
06
0E
07
642.9
0F
Notch depth selection
Setting
0
1
2
3
Servo motor rotation direction
CCW
A phase
B phase
A phase
B phase
1
or
2
Frequency
Frequency
Setting
562.5
10
281.3
500
11
264.7
450
250
12
409.1
13
236.8
375
14
225
346.2
15
214.3
321.4
16
204.5
300
17
195.7
Depth
Gain
40dB
Deep
14dB
to
8dB
Shallow
4dB
5 - 13
Initial
Value
0000
CW
0000
).
Setting
Frequency
18
187.5
19
180
173.1
1A
1B
166.7
1C
160.1
1D
155.2
1E
150
1F
145.2
Setting
Unit
Range
Refer to
Name
and
function
column.
Refer to
Name
and
function
column.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents