13
Aligning the button clamp
.28
Requirement
After selecting parameter "610", (at the value "4") the needle should penetrate in the
centre hole of button gauge 2.
1
3
Fig. 13 - 26
● Remove loading plate 1.
● Switch on the machine and set parameter "610" at value "4" (button gauge: centre).
● Insert and align button gauge 2 (part no. 61-111 635-66).
● If necessary, correct the setting of button clamp 3 (screws 4).
● Switch off the machine.
● Remove the button gauge and fit the loading plate.
(only on the PFAFF 3307-3/01)
2
111-090
4
Adjustment
4