Pfaff 3307-3 Series Instruction Manual page 122

Table of Contents

Advertisement

Adjustment
122
Parame-
Group
Description
ter
200
204
Cut-out size of cloth plate (not on stem
wrapper), see Chapter 3.02 seam pat-
tern sizes
205
Missed stitch detection
I = off, II = on (not on stem wrapper)
206
Missed stitch detection threshold
(not on stem wrapper)
207
Fade-out stitches of the misses
stitch detection function
(not on stem wrapper)
208
1 – 120 = Display thread size of last pro-
gram (max. 120 stitches)
0 = Display calculated optimum thres-
hold (for input in para. "206"
(not on stem wrapper)
209
Air jet
I = off, II = on
Attention!
If the thread wiper is attached, the air jet
must be switched off!
210
Turn-on time air jet [s]
211
Initialize clamp at sewing start
I = off, II = on
400
401
Raise clamp delay [s]
(not on stem wrapper)
402
Start delay after clamp lowered [s]
(not on stem wrapper)
403
Delay before thread trimming [s]
(switching time to thread wiper forwards)
on stem wrapper:
Wait between spreader and thread trim-
ming (as control for thread trimming po-
sition)
404
Thread trimming time [s]
(time thread wiper remains in forward
position; on thread wrapper: Time till
spreader moves forwards)
405
Time between "thread clamp closed" and
"thread puller on" [s]
Setting
Set
range
value
1 - 6
1
I, II
I
0 - 999
120
0 - 9
6
0 -120
I, II
I
0 - 10
1
I, II
I
0,00 - 1,50
0
0,00 - 1,50
0
0,00 - 2,00
0,06
2,00
0,00 - 2,00
0,06
0,00 - 2,00
0,10