Section VI - Compressor Fluids

Converting to QuinSyn-Plus

normal Machines
To convert a clean machine presently using
any QuinSyn fluid (except QuinSyn-PG) to
QuinSyn-Plus - No flush required:
• Drain compressor thoroughly while hot,
including all the low areas, fluid lines
and the fluid cooler.
• Shut down and lockout the machine.
• Change the separator and all filters.
• Refill the reservoir and system with a full
charge of QuinSyn-Plus.
• Send a fluid sample to Quincy
Compressor Fluid Analysis at 200 hours.
To convert a clean machine presently using
QuinSyn-PG or mineral oil to QuinSyn-Plus,
flush according to flushing instructions on
page 54.
Varnished Machines
For slightly to extremely varnished
machines using mineral oils or PAO fluids,
flush the compressor with QuinSyn Flush
following the procedures outlined on page
55.
56

Converting to QuinSyn-XP

normal Machines
To convert a clean machine presently using
any QuinSyn fluid to QuinSyn-XP- No flush
required:
• Drain compressor thoroughly while hot,
including all the low areas, fluid lines
and the fluid cooler.
• Shut down and lockout the machine.
• Change the separator and all filters.
• Refill the reservoir and system with a full
charge of QuinSyn-Plus.
• Send a fluid sample to Quincy
Compressor Fluid Analysis at 200 hours.
To convert a clean machine presently using
mineral oil to QuinSyn-Plus, flush according
to flushing instructions on page 54.
Varnished Machines
For slightly to extremely varnished
machines using mineral oils or PAO fluids,
flush the compressor with QuinSyn Flush
following the procedures outlined on page
55.