Compressor Rotation
Compressor rotation is controlled by the
variable speed drive (drive motor only).
Correct connection of the drive motor (to
the drive) is verified at the factory. If the
drive motor is disconnected for any reason,
follow the wiring diagram supplied with the
drive motor when reconnecting the motor
to the drive to ensure proper rotation.
Warning!
O p e r a t i n g t h e c o m p r e s s o r w i t h
incorrect rotation will result in extreme
damage to the compressor and warranty
coverage will be voided.
Fan Rotation (air-cooled only)
Check the fan rotation prior to start-up.
Fan airflow should be outward, that is,
pushing the air through the coolers.
Quincy Compressor-QGV Series
Section III - Installation
7