Fluid Level - Quincy QGV-100 Instruction Manual

Variable speed drive air compressors
Table of Contents

Advertisement

Fluid Level

The correct fluid level is important for
the reliability of the compressor. The
fluid level is monitored by a sightglass
while the compressor is in operation. The
fluid level should be checked daily and
should be in the middle of the sightglass
(between 'minimum' & 'maximum') when
the compressor is running loaded. If a low
fluid level is observed, add enough fluid
to bring the fluid back to the proper level.
DO NOT OVER FILL. The correct fluid
capacity of QGV compressors is indicated
in the parts book supplied with the unit.
Caution!
To avoid damage to the compressor,
it is very important that the same type
of fluid be used when topping off the
fluid level in the compressor. Never
mix different types of fluid.
To top off the fluid level (add fluid):
• Turn the compressor off by the main
switch and perform proper lockout/
tagout procedure.
FLUID
FILL PORT
FLUID LEVEL
SIGHTGLASS
FLUID
DRAIN PORT
Quincy Compressor-QGV Series
Section V - Servicing
• Completely depressurize the
compressor circuits (reference
'Preparing for Maintenance or Service'
on page 28 and 'Safety' instructions on
page 30).
• Wait one minute and check the fluid
level.
• Unscrew the fluid fill plug.
Caution!
Hot fluid under pressure could cause
death or serious injury. Do not remove
the fluid fill plug and attempt to
add fluid to the reservoir while the
compressor is in operation or when the
system is under pressure.
• Add the required amount of fluid
through the fluid fill opening.
• Reinstall the fluid fill plug.
• Restart the compressor and recheck the
fluid level.
35