Section VI - Compressor Fluids

Cleaning and Flushing with QuinSyn Flush

normal Machines
To flush clean machines presently using:
Mineral Oils -
(A) - Drain compressor thoroughly while
hot including all the low areas.
- Shut down and lockout the
machine.
- Detach fluid lines and drain.
- Inspect the machine;
- if clean, change filters and separator
elements and proceed as follows:
• Fill with QuinSyn Flush and run machine
until it reaches normal operating
temperature.
• Drain the QuinSyn Flush and discard
in accordance with all local, state and
federal disposal regulations.
• Change the separator element and all
filters.
• Refill with a fresh charge of the QuinSyn
fluid selected for your machine.
• Send a fluid sample to Quincy
Compressor Fluid Analysis at 200 hours.
54
Polyalklene glycols (PAG) or Silicone -
• Drain compressor thoroughly as in (A).
• Fill machine with QuinSyn Flush and run
for 500 hours.
• Send fluid sample to Quincy
Compressor Fluid Analysis to determine
if further flushes are needed.
• Continue compressor operation until
results of fluid analysis are reported.
• Once the analysis indicates the machine
is clean, drain the flush, change the
separator element and all filters, and fill
with the QuinSyn fluid selected for your
machine.
• Send a fluid sample to Quincy
Compressor Fluid Analysis at 200 hours.
Quincy Compressor-QGV Series