Converting To Quinsyn Xp; Converting To Quinsyn Plus - Quincy QGB Series Instruction Manual

Belt drive air compressors
Table of Contents

Advertisement

Converting to QuinSyn XP

Normal Machines
A. Any QuinSyn fluid - No flush required.
Drain Compressor thoroughly while
hot, including all the low areas, fluid
lines and the fluid cooler. Shut down
and lockout the machine. Change
the separator and all the filters on the
compressor. Refill the reservoir and
system with a full charge of QuinSyn
XP.
B. Mineral Oils - Drain compressor
thoroughly while hot including all the
low areas. Shut down and lockout
the machine. Detach lines and drain.
Inspect machine; if clean, change
filters and separator elements. Fill
with QuinSyn Flush and run machine
until it reaches normal operating
temperature. Drain and refill with
a fresh charge of new QuinSyn
XP. Send a fluid sample to Quincy
Compressor
Fluid Analysis at 200
®
hours.
Varnished Machines
For slightly to extremely varnished
machines using mineral oils or PAO fluids,
flush the compressor with QuinSyn Flush
following the procedures outlined on
pages 52-53.
Section VII - Compressor Fluids

Converting to QuinSyn Plus

Normal Machines
A. Any QuinSyn fluid (except QuinSyn
PG) - No flush required. Drain
Compressor thoroughly while hot,
including all the low areas, fluid lines
and the fluid cooler. Shut down and
lockout the machine. Change the
separator and all the filters on the
compressor. Refill the reservoir and
system with a full charge of QuinSyn
Plus.
B. Mineral Oils and QuinSyn PG - Drain
compressor thoroughly while hot
including all the low areas. Shut
down and lockout the machine.
Detach lines and drain. Inspect
machine; if clean, change filters and
separator elements. Fill with QuinSyn
Flush and run machine until it reaches
normal operating temperature. Drain
and refill with a fresh charge of new
QuinSyn Plus. Send a fluid sample to
Quincy Compressor
200 hours.
Varnished Machines
For slightly to extremely varnished
machines using mineral oils or PAO fluids,
flush the compressor with QuinSyn Flush
following the procedures outlined on
pages 52-53.
Quincy Compressor-QGB
Fluid Analysis at
®
Back to Table of Contents
63

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Qgb 20Qgb 30Qgb 25Qgb 50Qgb 60Qgb 40

Table of Contents