Fluid Analysis Program - General

Quincy's fluid analysis program is offered
to all customers using QuinSyn fluids
in Quincy Compressor
Compressors. This service provides
optimum drain intervals for compressors
operating on QuinSyn fluids. Monitoring of
the total acid number (TAN), barium level
and/or viscosity throughout the life of the
fluid provides maximum protection to your
machine, while best utilizing the extended
life features of QuinSyn.
The fluid analysis provides historical
information, detailing items such as
hours on the fluid, viscosity and total acid
number (TAN). Should results appear
unusual or suspicious, a detailed analysis
can pinpoint specific contaminants. A
detailed report is furnished to you,
your Quincy Distributor and the Quincy
Compressor
factory upon completion of
®
the fluid analysis.
Although QuinSyn fluids are rated by hours
of life expectancy under normal operating
conditions, it is recommended that fluid
samples be taken every 500 to 2000 hours
Rotary Screw
®
Quincy Compressor-QGB
Section VII - Compressor Fluids
and sent to Quincy Compressor
Analysis until a history of performance
in a specific compressor application is
established. Once the appropriate drain
interval is established, the frequency of
the fluid analysis can be reduced unless
operating conditions change.
notiCe!
All Quincy Compressor
airend warranty programs require
that fluid samples be sent to Quincy
Compressor
Fluid Analysis a minimum
®
of every 2,000 hours.
The depletion of antioxidants, change of
viscosity, barium and acid levels all occur
with time. It is extremely important to
change QuinSyn before the antioxidants
are completely depleted. If the fluid is left
in the compressor beyond its useful life,
removing all of the spent fluid is difficult.
The oxidation products remaining can
considerably shorten the life of the new fill
of QuinSyn fluid.
Back to Table of Contents