Installation - Quincy QGB Series Instruction Manual

Belt drive air compressors
Table of Contents

Advertisement

To provide safe, breathable air,
compressor must be capable of producing
at least Grade D breathing air as
described in Compressed Gas Association
Commodity Specification G7.1-1966.
Special filtering, purifying and associated
alarm equipment must be used to convert
compressed air to "Breathing Air." Other
special precautions must also be taken.
Refer to OSHA 29 CFR 1910.134.

Installation

Electronic timer operated auto drains
are installed on integrated dryers. Auto
drains include a particle strainer upstream
from the drain valve. To clean, close the
shut-off valve and depressurize the drain
line. All drain outlets may be combined
for condensate disposal. Dispose the
condensate in compliance with local and
federal government requirements.
Warning!
Drain outlet tubing will periodically
contain pressurized air. An unsecured
drain tube will whip around potentially
causing bodily injury.
Section V - Integrated Dryer (option)
DISCLAIMER OF WARRANTY If this unit is
used to produce breathing air, the special
equipment and precautions expressed in
OSHA 29 CFR 1910.134 for specifications
of the necessary equipment and special
precautions to make Breathing Air MUST
BE used or any warranties are VOID
and manufacturer disclaims any liability
whatsoever for loss, personal injury or
damage.
Do not combine any two or more drain
inlet lines through one single automatic
drain valve. This will reduce or eliminate
the proper drainage.
W i r i n g t o t h e d r y e r m u s t m e e t
the national (NEC) and local code
requirements. Check the voltage
specified on the nameplate to the
electrical power connecting to the
dryer. Electrical connections must be
made by an electrician.
Quincy Compressor-QGB
Caution!
Warning!
Back to Table of Contents
25