Appendix B - Technical Data
QGB 20
Full Load Operating Pressure
Max. Operating Pressure
Min. Operating Pressure
Max. Ambient Operating Temp.
Min. Ambient Operating Temp.
Compressor Drive Motor
Inlet Capacity
Service Line Connection Size
Rotor Diameter
Male Rotor Speed
Male Tip Speed
Aftercooling Data
Heat Rejection - Fluid Cooler
Aftercooler
Aftercooler Approach to Cooling
Air (@ std. conditions)
Max Static Backpressure
Fan Motor
Fan Motor
Fan Flow
Compressor Fluid Data
Fluid Flow
Total Fluid Capacity
Reservoir Fluid Capacity
Normal Airend Discharge Temp.
Typical Fluid Carryover
Sound Data (at 1 meter)
Unenclosed
Standard Enclosure
Energy Consumption (air-cooled)
Full Load Drive Motor HP
Unloaded Drive Motor HP
Fan Motor HP
FL Drive Motor Consumption
FL Fan Motor Consumption
Total Package Consumption
Total Package Specific Power
Dimensions
Length
Width
Height
86
Back to Table of Contents
psig
psig
psig
°F
°F
Nameplate HP
acfm
In. (FLG)
mm
rpm
m/sec
btu/min
btu/min
°F
in./H
0
2
Nameplate HP
rpm
cfm
gpm
gal
gal
°F
ppm
dB(A)
dB(A)
Bhp
Bhp
Bhp
kW
kW
kW
kW/100 cfm
bhp/100 cfm
in (mm)
in (mm)
in (mm)
Quincy Compressor-QGB
100
125
150
115
140
165
75
130
40
20
89
80
70
1
85
6589
5962
5287
29.3
26.5
23.5
728
107
15
0.125
1
3524
1530
5.2
5.8
6.4
2.7
1.3
190
<3
77
70
21.3
5.2
0.8
17.6
17.08
17.08
0.8
0.75
0.75
18.03
17.93
17.93
20.3
22.4
25.6
24.8
27.6
31.6
63 (1600)
34 (834)
47 (1190)
™
175
190
59
4602
20.5
6.8
17.08
0.75
17.93
30.4
37.5