Quincy QGB Series Instruction Manual page 95

Belt drive air compressors
Table of Contents

Advertisement

QGB 60
Full Load Operating Pressure
Max. Operating Pressure
Min. Operating Pressure
Max. Ambient Operating Temp.
Min. Ambient Operating Temp.
Compressor Drive Motor
Inlet Capacity
Service Line Connection Size
Rotor Diameter
Male Rotor Speed
Male Tip Speed
Aftercooling Data
Heat Rejection - Fluid Cooler
Aftercooler
Aftercooler Approach to Cooling
Air (@ std. conditions)
Max Static Backpressure
Fan Motor
Fan Motor
Fan Flow
Compressor Fluid Data
Fluid Flow
Total Fluid Capacity
Reservoir Fluid Capacity
Normal Airend Discharge Temp.
Typical Fluid Carryover
Sound Data (at 1 meter)
Unenclosed
Standard Enclosure
Energy Consumption (air-cooled)
Full Load Drive Motor HP
Unloaded Drive Motor HP
Fan Motor HP
FL Drive Motor Consumption
FL Fan Motor Consumption
Total Package Consumption
Total Package Specific Power
Dimensions
Length
Width
Height
Appendix B - Technical Data
psig
psig
psig
°F
°F
Nameplate hp
acfm
In. (FLG)
mm
rpm
m/sec
btu/min
btu/min
°F
in. H20
Nameplate hp
rpm
cfm
gpm
gal
gal
°F
ppm
dB(A)
dB(A)
Bhp
Bhp
Bhp
kW
kW
kW
kW/100 cfm
bhp/100 cfm
in (mm)
in (mm)
in (mm)
69.5 (1765)
Quincy Compressor-QGB
100
125
115
140
75
75
115
115
40
40
60
284
251
1.25
1.25
127.5
127.5
5126
4608
34.2
30.7
2148
327
17.9
0.125
2
3481
3370
15
16.7
8.5
5.4
190
<3
89
79
67.8
66.5
12.2
12.2
1.3
1.3
54.3
53.32
1.2
1.21
55.5
54.53
19.5
21.7
24.3
27.0
72 (1830)
34 (834)
Back to Table of Contents
150
165
75
115
40
220
1.25
127.5
4109
27.4
18.4
64.2
12.2
1.3
51.48
1.21
52.69
24.0
29.8
91

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Qgb 20Qgb 30Qgb 25Qgb 50Qgb 60Qgb 40

Table of Contents