Setting Up Fixture Control - GLP Highlander Wash Quick Start And Safety Manual

Hide thumbs Also See for Highlander Wash:
Table of Contents

Advertisement

www.glp.de
Release the tilt lock, check the clearance around the head and make sure that
nobody is looking directly at the fixture. Then apply power to the power input cable.
Installing power connectors on the input cable
It is possible to install a cord cap / mains power plug that is suitable for your local
convenience receptacles / power sockets on the supplied power input cable. If you do
this, check that the cord cap / plug is rated minimum 250 V, 16 A, that it has a
connection to ground / earth and that it has an integral cable grip. Follow the cord cap
/ plug manufacturer's assembly instructions.
If you need to install a Neutrik powerCON TRUE1 connector on a power cable, follow
the instructions given on the Neutrik website at www.neutrik.com.
Respect the color coding used in the supplied power cable and in your local mains
power wiring system. US and EU systems use the color coding shown below:
US system
EU system

Setting up fixture control

The Highlander Wash can be controlled via USITT512 DMX over a standard DMX cable
link, Art-Net network or sACN network.
If you would like advice with planning and installing a suitable control link, your GLP
supplier will be happy to provide assistance.
DMX
See 'Overview' on page 13. The fixture has 5-pin XLR IN and THRU sockets for connection
to a DMX cable link.
Connectors use standard DMX pinout:
● Pin 1 = Ground
● Pin 2 = Negative / data cold
● Pin 3 = Positive / data hot.
● Pins 4 and 5 are not used.
To configure the fixture for DMX control over a DMX cable link, open the menus in the
fixture's control panel and make the following adjustments:
In the first menu (root menu), set the fixture's DMX address to a suitable address.
In the Control Protocol menu, set the control protocol to DMX (the default setting).
These settings will not be affected if you apply a Load Default Settings command in the
fixture's control panel, but they will be returned to factory defaults if you apply a Load
Factory Backup command in the fixture's control panel.
To link fixtures in cabled DMX daisy-chains using their XLR connectors, use certified DMX
cable only.
20
Live or L
Neutral or N
Black
White
Brown
Blue
Ground / Earth or
Green
Yellow/green
Highlander Wash Quick Start and Safety Manual