German Light Products
Art-Net
The fixture's Ethernet port is suitable for connection to an Art-Net network.
To configure the fixture to receive control data via Art-Net, open the menus in the
fixture's control panel and make the following adjustments:
In the first menu (root menu), set the fixture's DMX address to a suitable address.
In the Control Protocol menu, set the control protocol to Art-Net.
Configure all fixtures with their own unique IP addresses. To do this, you can either:
● set fixtures to generate their own IP addresses by choosing the ranges 2.x.x.x or
10.x.x.x (Art-Net specification),
● set fixtures to acquire IP addresses automatically by DHCP, or
● assign IP addresses manually by entering individual IP addresses and Subnet mask.
Select an Art-Net port/universe from 00000 (Network 0 / Subnet 0 / Universe 0) to
32767 (Network 7 / Subnet 15 / Universe 255). Note that the first Art-Net universe is
considered to be universe number 00000, not 00001.
These settings will not be affected if you apply a Load Default Settings command in the
fixture's control panel, but they will be returned to factory defaults if you apply a Load
Factory Backup command in the fixture's control panel.
Note that it is possible to transmit DMX data as broadcast or unicast packages via Art-
Net. If a large number of universes (more than 30) is broadcast, data loss can occur. If
you suspect that this is happening, configure your console to unicast Art-Net DMX
packages to fixtures, or switch to sACN.
To link fixtures in Art-Net daisy-chains, use CAT 6 or higher Ethernet cable.
sACN
The fixture's Ethernet port is suitable for connection to an sACN network.
To configure the fixture to receive control data via sACN, open the menus in the fixture's
control panel and make the following settings:
In the first menu (root menu), set the fixture's DMX address to a suitable address.
In the Control Protocol menu, set the control protocol to sACN.
Configure all fixtures with their own unique IP addresses. To do this, you can either:
● set fixtures to generate their own IP addresses by choosing the ranges 2.x.x.x or
10.x.x.x (Art-Net specification),
● set fixtures to acquire IP addresses automatically by DHCP, or
● assign IP addresses manually by entering individual IP addresses and Subnet mask.
Select an sACN universe from 00001 to 63999.
These settings will not be affected if you apply a Load Default Settings command in the
fixture's control panel, but they will be returned to factory defaults if you apply a Load
Factory Backup command in the fixture's control panel.
To link fixtures in sACN daisy-chains, use CAT 6 or higher Ethernet cable.
Highlander Wash Quick Start and Safety Manual
®
21