GLP Highlander Wash Quick Start And Safety Manual page 18

Hide thumbs Also See for Highlander Wash:
Table of Contents

Advertisement

www.glp.de
Bolt a rigging clamp to each omega bracket using a suitable grade 8.8 minimum
steel bolt and self-locking nut.
See Figure 4. Line up the two camlock quarter-turn pins in each of the two omega
brackets with the camlock fastener points B in the base of the fixture and turn all
locking levers a full 90° clockwise to lock the brackets to the fixture.
Fasten the rigging clamps securely around a rigging truss chord or similar bar.
Secure the fixture against clamp failure as described in 'Securing the fixture with a
safety cable' on page 16.
Make sure that the head will not collide with another fixture or any other object
when it moves through its full pan and tilt ranges.
Sideways Mounting
For sideways mounting (i.e. mounting with the fixture's yoke pointing horizontally), the
Highlander Wash may be clamped to a vertical truss on condition that you:
● use two half-coupler type rigging clamps that completely encircle the truss chord
and that can hold the weight of the fixture securely, and
● install the fixture with one half-coupler rigging clamp directly above the other on a
vertical truss chord.
See 'Mounting directly with rigging clamps' on page 17 for instructions on how to install
the fixture using rigging clamps.
Do not attempt to mount the Highlander Wash sideways on a horizontal truss.
18