Note: max load current 400mA (if control the brake motor by SO signal, please confirm the
brake current, if it is larger than 400mA, please use intermediate relay)

3-1-2-4. Analog input circuit

DS3-2□P□-PQA
DS3-4□P□-PQA
13(analog GND) come from CN1 DB15, refer to chapter 3-1-1-4.
Optocoupler type
Servo drive
Relay type
Servo drive
Upper device
Note: analog terminal 11 (T-REF analog torque), 12(T-REF analog speed),
Analog signal is speed command or torque command. Input impedance:
• speed command input: about 13KΩ
• torque command input: about 13KΩ
• max allowable voltage of input signal is ± 10V
upper device
upper device
servo drive