Printer Interface; Ethernet Interface - Motorola MVME197LE Installation Manual

Hide thumbs Also See for MVME197LE:
Table of Contents

Advertisement

Solution Systems Technologies Inc.
Board Level Hardware Description
1
operate at synchronous bit rates up to 64k bits per second. It uses RXD, CTS,
DCD, RTS, and DTR. It also interfaces to the synchronous clock signal lines.
Refer to the MVME197LE, MVME197DP, and MVME197SP Single Board
Computers Programmer's Reference Guide for drawings of the serial port interface
connections.
All four serial ports use EIA-232-D drivers and receivers located on the main
board, and all the signal lines are routed to the I/O connector. The
configuration headers are located on the MVME712X transition board. An
external I/O transition board such as the MVME712X should be used to
convert the I/O connector pinout to industry-standard connectors.
The interface provided by the PCCchip2 allows the 16-bit CD2401 to appear at
contiguous addresses; however, accesses to the CD2401 must be 8 or 16 bits.
32-bit accesses are not permitted. Refer to the CD2401 data sheet and to the
PCCchip2 chapter in the MVME197LE, MVME197DP, and MVME197SP Single
Board Computers Programmer's Reference Guide for detailed programming
information.
The CD2401 supports DMA operations to local memory. Because the CD2401
does not support a retry operation necessary to break VMEbus lock conditions,
the CD2401 DMA controllers should not be programmed to access the
VMEbus. The hardware does not restrict the CD2401 to onboard DRAM.

Printer Interface

The MVME197LE has a Centronics-compatible printer interface. The printer
interface is provided by the PCCchip2. Refer to the PCCchip2 chapter in the
MVME197LE, MVME197DP, and MVME197SP Single Board Computers
Programmer's Reference Guide for detailed programming information and for
drawings of the printer port interface connections.

Ethernet Interface

The 82596CA is used to implement the Ethernet transceiver interface. The
82596CA accesses local RAM using DMA operations to perform its normal
functions. Because the 82596CA has small internal buffers and the VMEbus
has an undefined latency period, buffer overrun may occur if the DMA is
programmed to access the VMEbus. Therefore, the 82596CA should not be
programmed to access the VMEbus.
Every MVME197LE module is assigned an Ethernet Station Address. This
address is $08003E2XXXXX, where XXXXX is the unique 5-nibble number
assigned to the board (i.e., every MVME197LE has a different value for
XXXXX).
1-10
Solution Systems Technologies Inc.
720-565-5995 | info@solusys.com | www.solusys.com
720-565-5995 | info@solusys.com | www.solusys.com
Installation Guide

Advertisement

Table of Contents
loading

Table of Contents