Port number is the zero index of the Angelo series card. For exam-
ple, if there are two PCI-RTV-24 Angelo cards (card 0, card 1) in
the system, and each PCI-RTV-24 has four ports, the first port of
card 0 is "0", and the first port of card 1 is "4."
Interval:
Indicates the trigger output interval, the valid range is from 0 to
253, the definition is as following
0: 16ms
32: 12ms
128: 8ms
253: 60µs
Multiplex:
Indicates the trigger output ports in Angelo series cards.
Bit 0: Port 0 on each card. 0 for disable, 1 for enable.
Bit 1: Port 1 on each card. 0 for disable, 1 for enable.
Bit 2: Port 2 on each card. 0 for disable, 1 for enable.
Bit 3: Port 3 on each card. 0 for disable, 1 for enable.
For example:
Multiplex = 1, only port 0 in each Angelo series card gener-
ates a trigger output.
Multiplex = 2, only port 1 in each Angelo series card gener-
ates a trigger output.
Multiplex = 15, four ports in each Angelo series card gener-
ates a trigger output.
@ Return Code
0: ERROR_NoError
-7: ERROR_Not_Initialized – Make sure the port has been
initialized by "AngeloRTV_Initial".
-9: ERROR_Invalid_PortNo – Please input the correct
"PortNo" parameter.
@ Example
<VC/BCB >
AngeloRTV_Trigger_Config
AngeloRTV_Trigger_Start
120