ADLINK Technology RTV Series User Manual page 117

Multi-channel real-time video frame grabber series
Table of Contents

Advertisement

@ Argument
PortNo:
Port number is the zero index of the Angelo series card. For exam-
ple, if there are two PCI-RTV-24 Angelo cards (card 0, card 1) in
the system, and each PCI-RTV-24 has four ports, the first port of
card 0 is "0", and the first port of card 1 is "4."
Status:
The digital input or digital output status
0 Low
1 High
Logic:
The digital input interrupt condition
0: Active Low
1: Active High
Offset:
The offset address of the EEPROM. This parameter is valid
between 0 and 127
Value: The value in Byte data type, this parameter is valid between
0 and 255.
LEDStatus:
Use the parameter to set the LED status.
LEDStatus = 1: High
LEDStatus = 0: Low
@ Return Code
0: ERROR_NoError
-7: ERROR_Not_Initialized – Make sure the port has been
initialized by "AngeloRTV_Initial".
-9: ERROR_Invalid_PortNo – Please input the correct
"PortNo" parameter.
-15: ERROR_Invalid_Address – a valid offset address is
between 0 and 127
@ Example
<VC/BCB >
AngeloRTV_Set_GPIO_Sts –
Function Library
107