5.9 Software Trigger

@ Name
AngeloRTV_Trigger_Config (PortNo,Interval)
Sets software trigger configuration(Only for PCI-RTV24, cPCI-
RTV-24, cPCI-RTV44)
AngeloRTV_Trigger_Start (CardNo, Multiplex)
Generates single or multiple trigger output simultaneously(Only for
PCI-RTV24, cPCI-RTV-24, cPCI-RTV44)
@ Description
AngeloRTV_Trigger_Config:
Configures the pulse output interval.
AngeloRTV_Trigger_Start:
Generates a one shot pulse output for single or multiple ports.
@ Syntax
C/C++ (Windows/CE.NET)
I16 AngeloRTV_Trigger_Config(U16 PortNo,U16
Interval);
I16 AngeloRTV_Trigger_Start(U16 CardNo,U16
Multiplex);
Visual Basic (Windows/CE.NET)
AngeloRTV_Trigger_Config (ByVal PortNo As
Integer, ByVal Interval As Integer) As
Integer
AngeloRTV_Trigger_Start (ByVal CardNo As Integer,
ByVal Multiplex As Integer) As Integer
Delphi (Windows)
AngeloRTV_Trigger_Config (PortNo:Smallint;
Interval:Smallint):Smallint;
AngeloRTV_Trigger_Start (CardNo:Smallint;
Multiplex:Smallint):Smallint;
@ Argument
CardNo:
Card number is the zero index in Angelo series card. For example,
if there are two Pci-RTV-24 Angelo cards (card 0, card 1) in the
system, "CardNo" of card 0 is 0, and 1 for card 1.
PortNo:
Function Library