Troubleshooting
Digital error i-ndicator:
In case of SF4C-F15□,
Error indicator (yellow) blinks more
than 10 times.
Effect from noise or failure of internal
circuit
Digital error indicator:
In case of SF4C-F15□,
Error indicator (yellow) blinks 31 times.
Receiver error
<Digital error indicator " " lights up (Except SF4C-F15□)>
Synchronization + wire (orange) or synchronization - wire
(orange / black) error.
Synchronization + wire (orange) or synchronization - wire
(orange / black) is short-circuited or disconnected.
Receiver error.
<Test input indicator (orange) lights up>
The device is in the test input condi-
tion. (Device error or interlock setting
error)
<All beam-axis adjustment indicators (red) light up>
The beam channel with its fixed blanking function set into
valid receives light.
The safety input 1 wire (gray) and the safety input 2 wire (gray
/ black) is not wired.
<Operation indicator remains lit in red (light is not received)>
The beam channels are not correctly aligned.
If the device does not work normally after checking the items above, please consult Panasonic Industrial De-
vices SUNX.
<Reference>
About counting blinks of the error indicator, count blinks from 2 seconds of no blinking.
72
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
Cause
Affected by noise.
Internal circuit is broken
down.
Receiver is in lockout state. Check an digital error indicator (red) of receiver.
Cause
Cause
Error indicator (yellow)
lights up or blinks.
Test input / reset input wire
(pink) is open when select-
ing auto reset.
Test input / reset input wire
(pink) is connected to 0V or
+V when selecting manual
reset.
Cause
Cause
Check the noise status around this device.
When the synchronization + wire (orange) and synchronization -
wire (orange / black) is extended with a cable other than exclusive
2
cable, use a 0.2mm
or more shielded twisted pair cable.
If this device still does not work, confirm number of blinks of the
error indicator and call to our local office.
Connect the synchronization + wire (orange) and synchronization - wire
(orange / black) properly.
Refer to "2-5 Wiring."
Check the operation of the receiver side.
Check the error contents of the digital error indicator.
Wire the test input / reset input wire (pink) to 0V or +V.
Refer to "2-5 Wiring."
Open the test input / reset input wire (pink).
Refer to "2-5 Wiring."
Turn ON the power supply after checking the installation status.
Wire the safety input 1 wire (gray) and the safety input 2 wire (gray /
black) correctly.
Align the beam channels.
Refer to "2-6 Adjustment."
Align the top / bottom direction of the beam channel between emitter
and receiver.
© Panasonic Industrial Devices SUNX Co., Ltd. 2016
Remedy
Remedy
Remedy
Remedy
Remedy