Panasonic SF4C Series Instruction Manual page 35

Ultraslim light curtain/type4
Hide thumbs Also See for SF4C Series:
Table of Contents

Advertisement

<For NPN output>
Receiver
Emitter
Gray cable
Gray cable
(with black line)
Interlock function
External device monitor function Valid
Auxiliary output
The device output is selected depending on the connecting state of the output polarity setting wire (shield). Incorrect
wiring may cause the lockout state.
* Symbols
Switch S1
● Test input / Reset input
0 to +2.5V (source current 5mA or less): ON, Open: OFF
K1, K2: External device (Forced guided relay or magnetic contactor)
Note: For resetting, refer to "3-2 Interlock Function."
© Panasonic Industrial Devices SUNX Co., Ltd. 2016
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
(Red) Muting lamp output
(Yellow) Override input
(Pale purple) Interlock setting input
(Brown) +V
(Yellow-green / Black) Auxiliary output
(Shield) Output polarity setting wire
(Gray) Safety input 1
(Gray / Black) Safety input 2
(Pink) Test input / Reset input
(Blue) 0V
(Orange) Synchronization +
(Orange / Black) Synchronization -
(Orange / Black) Synchronization -
(Orange) Synchronization +
(Yellow-green) External device monitor input
(Brown) +V
(Black) Control output 1 (OSSD 1)
(White) Control output 2 (OSSD 2)
(Shield) Output polarity setting wire
(Blue) 0V
(Sky-blue / White) Muting input 1
(Sky-blue / Black) Muting input 2
(Gray) Large multi-purpose indicator input 1
(Gray / Black) Large multi-purpose indicator input 2
Invalid (Auto reset)
Can be used
Load
S1
K1
K2
K1
K2
Wiring
+
24V DC
%
-