Panasonic SF4C Series Instruction Manual page 67

Ultraslim light curtain/type4
Hide thumbs Also See for SF4C Series:
Table of Contents

Advertisement

<Wiring example for NPN output>
When using this device with NPN output, connect a NPN output type safety sensor.
Connect the emitter of this device and the receiver of the safety sensor as follows.
In case of using lead wires other than those described below, perform wiring depending on your application.
For details, refer to "2-5 Wiring."
Emitter of the device
Safety input 1 wire (gray)
Safety input 2 wire (gray / black) Control output 2 (OSSD 2) wire (white) [or control output 1 (OSSD 1) wire (black)]
+V wire (brown)
0V wire (blue)
Safety sensor
Receiver
Emitter
Gray cable
Gray cable
(with black line)
This device
Receiver
Emitter
Gray cable
Gray cable
(with black line)
● Safety input
Short-circuit (source current 5 to 10mA): Valid, Open: Invalid
© Panasonic Industrial Devices SUNX Co., Ltd. 2016
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
Receiver of the safety sensor
Control output 1 (OSSD 1) wire (black) [or control output 2 (OSSD 2) wire (white)]
(Blue) 0V
(Shield) Output polarity setting wire
(Brown) +V
(Orange) Synchronization +
(Orange / Black) Synchronization -
(Orange / Black) Synchronization -
(Orange) Synchronization +
(Blue) 0V
(Brown) +V
(Shield) Output polarity setting wire
(Black) Control output 1 (OSSD 1)
(White) Control output 2 (OSSD 2)
(Gray) Safety input 1
(Gray / Black) safety input 2
(Brown) +V
(Shield) Output polarity setting wire
(Blue) 0V
(Orange) Synchronization +
(Orange / Black) Synchronization -
(Orange / Black) Synchronization -
(Orange) Synchronization +
(Brown) +V
(Shield) Output polarity setting wire
(Black) Control output 1 (OSSD 1)
(White) Control output 2 (OSSD 2)
(Blue) 0V
+V wire (brown)
0V wire (blue)
K1
K2
Functions
+
24V DC
%
-
67

Hide quick links: