82
Display:
Description:
Cause and Remedy:
13.16 Flame return gate BSK (5038, 5039, 5040)
Display:
Description:
Cause and Remedy:
Display:
Description:
Cause and Remedy:
Display:
Description:
Cause and Remedy:
13.17 Suction system (Fault 5043)
Display:
Description:
Cause and Remedy:
PE 607 USA_FA 2.1
Not enough draught
Flue gas sensor or flamm-
roomtemperature-sensor
soiled
[5036] PE Flame supervision fault
Flame supervision fault, minimum flue gas temperature not reached during heating
up at full power – Input FRT
No pellets available
[5038] PE Flame return gate open
Flame return gate open fault (BSK - 1 2)
Flame return gate
unplugged
Flame return gate does
not reach OPEN limit
switch
No signal although open
STB on the burner has
triggered
[5039] PE Flame return gate closed
Flame return gate open fault
Flame return gate
unplugged
Flame return gate does
not reach CLOSE limit
switch
No signal although closed
STB on the burner has
triggered
[5040] PE Flame return gate limit switch
Both flame return gate limit switches (BSK 1-2 and BSK 3-4) are closed at the same
time
Both limit switches
activated
Suction system
Hopper cannot be filled up even after 3 suction cycles
Storage room empty
Extraction system is
blocked
Check ventilation flap, funktion radial fan, draught
free
Check Flue gas sensor or flammroom-temperatu-
re-sensor
Fill up with pellets
Connect up flame return gate and check cable
connections
Check ball valve to see if it is jammed
Check cables and flame return gate
Surface temperature of the burner is too high
Connect up flame return gate and check cable
connections
Check whether ball valve is jammed, check ball
valve throughway to see if foreign objects are pre-
venting it from closing
Check cables and flame return gate
Surface temperature of the burner is too high. The
boiler switches to fault mode.
Check flame return gate, check cables, check
connectors
Fill up with pellets
Clear extraction system