Connecting To The Power Supply; Plugs On The Boiler Control Unit - Okofen PELLEMATIC SmartXS Installation Manual

Table of Contents

Advertisement

46
1 1 2 2

Connecting to the power supply

12.1 Plugs on the boiler control unit

The designation of the plugs must correspond with the labeling of plug-in positions.
Designation
Number
X1A
3 2 GND 1
X1B
3 2 GND 1
X2
5 4
R1
46 45
R2
44 43
AF
42 41
KF
8 9
UP
2 3 4
AE2
5 6 7
AK
10 8
FRT
12 13
RGF
14 15
PWM SZ
16 17
18 19
Analog IN
BR1
7 8
PWM UW
11 12
ESAV
32 33 34
DE 1
37 36 35
DE 2
40 39 38
KAPZW
26 25 24
KAPRA
5 4 3
BSK
6 5 4 3 2 1
PE L N
X21
VAK
56 PE 55
ZUEND
N PE 22
AV
52 PE 51
RES 2
54 PE 53
MA
48 PE 47
RM
15 PE N
SM
19 20
SZ
17 PE N
UW
13 PE N
STB
17 PE 19
NOT
41 43
PE 607 USA_FA 2.1
Voltage
Name of the sensor, motor or pump
24 Volt
Operating display
24 Volt
Heating controller
24 Volt
Power supply for 24V BUS-connections
Heating circuit sensor, AC sensor or room sensor
24 Volt
DHW sensor or AC sensor
24 Volt
24 Volt
Not used
24 Volt
Boiler sensor
24 Volt
Negative draft measuring
24 Volt
Not used
24 Volt
Disabling contact for existing boilers, optional stirling
engine
24 Volt
Combustion chamber sensor
24 Volt
Not used
24 Volt
PWM for a speed controlled A-Class Pump
24 Volt
external malfunction
24 Volt
Burner contact for extern controller (optional)
24 Volt
PWM for speed controlled high-efficiency pump
24 Volt
End switch ash box
24 Volt
Signaling Switch for position of the Ball lock
24 Volt
Not used
24 Volt
Capacitive sensor – hopper
24 Volt
Capacitive sensor – burner
24 Volt
Flame return gate
230 Volt
Power supply
230 Volt
Vacuum turbine
230 Volt
Ignition
230 Volt
De-ashing motor
230 Volt
Pump Optimize Stratification
230 Volt
not used
230 Volt
Magnetic valve and motor cleaning device
230 Volt
Relay fault signal
230 Volt
Flue gas fan
230 Volt
not used
230 Volt
Safety temperature sensor
230 Volt
Emergency stop heating
Connecting to the power supply

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents