Malfunction report
13.12 Motor extraction auger 1 - RA (Fault 5026)
Display:
Description:
Cause and Remedy:
13.13 Hopper motor (Fault 5028)
Display:
Description:
Cause and Remedy:
13.14 Emergeny OFF/ Safety temperature (Fault 5032, 5033)
Display:
Description:
Cause and Remedy:
Display:
Description:
Cause and Remedy:
13.15 Temperature Combustion chamber sensor/Flue gas sensor (Fault 5034, 5036)
Display:
Description:
Cause and Remedy:
[5026] Motor ext auger1
Storage room auger 1 motor defect – Output RA
Motor unplugged
motor is jammed
Motor defect
Thermic contact triggered
Motor not running
[5028] Hopper motor
Hopper suction fan fault. Output RES1.
Motor unplugged
Motor defect
[5032] Emergeny OFF – NOT AUS
Emergency OFF has been actuated – Input NOT-AUS
Emergency OFF
unplugged
Emergency OFF button
has been pressed
Emergency OFF defect
[5033] Safety temperature - STB
Safety temperature limiter has tripped – Input STB
Safety temperature limiter
unplugged
Safety temperature limiter
has tripped
Safety temperature limiter
defect
A 230V Output is defect
[5034] PE Ignition fault / Pellets available?
Minimum temperature Combustion chamber sensor/Flue gas sensor not reached
durring the ignition phase
No pellets available
Ignition electrode defect
Ignition nozzle blocked
Plug in motor, check cable connections
►
Remove pellets and dust from auger and make su-
►
re auger rotates freely
Replace motor
►
Let motor cool down
►
Check thermic contact
►
Plug in motor, check cable connections
►
Replace motor
►
Connect up Emergency OFF and check cable
►
connections
Reset Emergency OFF switch
►
Replace Emergency OFF switch
►
Connect up safety temperature limiter and check
►
cable connections
Let boiler cool down and reset safety temperature
►
limiter
Replace safety temperature limiter
►
Check 230V Outputs
►
Fill up with pellets
►
Check ignition electrode (approx. 200Ω) replace if
►
required
Clean burner plate and ignition tube
►
Installation Manual PELLEMATIC® SmartXS
81