Display
Code
5067
Error Output ZW
5068
Error Output ES
13.1a Sensors KTY2K - Heating controller + Boiler Controller (Fault 1001 to 1020 and 5000 to 5007) – Sen-
sor break
Type of fault
Code:
Description:
Cause and Remedy:
PE 607 USA_FA 2.1
Input / Output
ZW
ES
Sensor break
1001
HC1 Flow BC
1002
DHW1 OnSensor BC
1003
Outside Sensor BC
1004
Boiler Sensor BC
1008
TPO1 BC
1009
TPM1 BC
1011
TPU1 BC
1012
Flow Energy1 BS
1013
Return Energy1 BS
1014
ExistBoiler1 BS
1017
Cascade OnSensor BC
1018
Cascade OffSensor BC
1019
Circulation Return1 BC
1020
DHW1 Off Sensor BC
5000
PE1 Reserve sensor1 BS
5002
PE1 Reserve sensor2 BS
5004
PE1 Outside sensor BS
5006
PE1 Boiler sensor BS
Measuring circuit of KTY sensor is open
sensor not connected
sensor defect
sensor cable defect
sensor temperature too high
Affected element
Boiler Controller
Boiler Controller
X4
X6
X2
X3
X7
X8
X9
X16
X17
X13
X3
X3
X14
X6
R1
R2
AF
KF
connect sensor, check plug
measure sensor (approx. 2kΩ at 25°C)
replace if required
replace sensor
sensor temperature above measuring
range (>110°C)
Malfunction report
Solution
table