14.1.3 Output Test

The output test is designed to test all outputs connected to the system (e.g. all motors, the alarm signal re-
lay, the solenoid valve and the recirculation pump).
By using the operative device and typing in the code, you can access the item output test in the menu
general.
You can control the required output with ON / OFF and choose the power input 0 -100%.
Designation
Motor suction fan
the suction fan on the hopper is
VAK
running
Ignition
the electrode is working: you can view
ZUEND
the current draw at the control unit af-
ter it has been switched on.
Motor hopper
The hopper motor is running.
RES 1
Solenoid valve
the solenoid valve switches over and
RM
you can hear it click
Note:
Low temperature systems only
Fault signal relay
the relay switches on and off: you can
SM
hear it clicking on and off
Flue gas fan
the flue gas fan is running
SZ
Heating circuit
the heating circuit pump is running
pump
Note:
UW
only possible if the heating circuit
pump is connected
PE 607 USA_FA 2.1
Check if
The Output Test serves to check all connected
outputs:
• all motors
• relay fault signals
• magnet valves
• boiler controlled pumps
Note:
After choosing of one port, the operation will
be interrupted.
By leaving the menu output test the normal
operation will continue.
If not, then check
• the suction fan is connected
• the fuse is defective
• the motor is defective
• the wiring is correct
• Check the ignition electrode
• the wiring is correct
• the motor is defective
• the scrubber is connected
• the scrubber is defective
• the wiring is correct
• the fault signal relay is defective
• the wiring is correct
• the motor is defective
• the wiring is correct
• the Heating circuit pump is defective
Output Test