13.1c Sensors KTY2K - Heating controller + Boiler Controller (Fault 3001 to 3020) – other faults
Type of fault
Code:
Cause and Remedy:
13.2 Collektor sensor (Fault 1010, 2010, 3010)
Display:
Description:
Cause and Remedy:
Display:
Description:
Cause and Remedy:
Display:
Description:
Cause and Remedy:
PE 607 USA_FA 2.1
Other faults
3001
HC1 Flow
3002
DHW1 OnSensor
3003
Outside Sensor
3004
Boiler Sensor
3008
TPO1
3009
TPM1
3011
TPU1
3012
Flow Energy1
3013
Return Energy1
3014
ExistBoiler1
3017
Cascade OnSensor
3018
Cascade OffSensor
3019
Circulation Return1
3020
DHW1 Off Sensor
Sensor defect
Sensor cable defect
Sensor input defect
[1010] Collektor BC
Collector sensor fracture, measuring circuit of collector sensor (X15) is open
Sensor not connected
Sensor defect
Sensor cable defect
[2010] Collektor SC
Measuring circuit of collector sensor (X15) is shorted out
Sensor defect
Sensor cable defect
[3010] Collektor
Other fault at input X15
Sensor defect
Sensor cable defect
Input on heating controller
defect
X4
X6
X2
X3
X7
X8
X9
X16
X17
X13
X3
X3
X14
X6
Measure sensor (approx. 2kΩ at 25°
C), replace if required
Replace sensor
Replace Boiler controller
Check and correct wiring
Measure sensor (approx. 1,1kΩ at 25°C), replace if
required
Replace sensor
Measure sensor (approx. 1,1kΩ at 25°C), replace if
required
Replace sensor
Replace sensor
Replace sensor
Replace input on heating controller
Malfunction report