80
13.8 Motor turbine (Fault 5018)
Display:
Description:
Cause and Remedy:
13.9 Output 230V (Fault 5019, 5022, 5023)
Display:
Description:
Cause and Remedy:
1310 Output 230V-2 (Fault 5020, 5024, 5025, 5027, 5029, 5030)
Display:
Description:
Cause and Remedy:
13.11 Hopper Empty - Motor res 1 (Fault 5021)
Display:
Description:
Cause and Remedy:
PE 607 USA_FA 2.1
[5018] PE Motor Turbine
Vaccuum turbine not running (Exit VAK)
Motor unplugged
Motor defect
Fuse F1, suction circuit
board defective
[5019] PE Ignition
[5022] PE Magnetic valve
[5023] PE Motor cleaning
No function of output ZUEND (Ignition)/MA (Magnetic valve)/ RM (Motor cleaning)
Output unplugged
Current value above the
maximal Limit
Current value under the
minimal Limit
[5020] PE Motor ashbox (Output AV)
[5024] PE Flue gas fan (Output SZ)
[5025] PE Cirkulationspump (Output UW)
[5027] PE Motor ext auger2 (Output RES2)
[5029] PE Motor boiler auger (Output ES)
[5030] PE Combustion Fan (Output LUFT)
No function of the respective motor/pump/fan
Motor/pump/fan
unplugged
Motor/pump/fan defect
[5021] PE Hopper empty / Motor RES1 (for 36-56 kW, Pellematic Condens or
PEB)
No function of PE motor res 1
Motor unplugged
Motor defect
No pellets available
Plug in motor, check cable connections
►
Replace motor
►
Replace fuse
►
Connect plug, check cable wiring
►
Check limits
►
Check limits
►
Connect plug, check cable wiring
►
Replace motor/pump/fan
►
Plug in motor, check cable connections
►
Replace motor
►
Refill storage-Room / supply tank
►
Malfunction report