Storage systems

8 8
Storage systems
There are two methods for storing pellets: in a storage room with an auger feed system (version A) or in a
FleXILO fabric tank (version B). FleXILO fabric tanks can be located inside the central heating room, storage
room or protected from wet and sun outside.
D D a a m m a a g g e e t t o o p p r r o o p p e e r r t t y y a a n n d d l l o o s s s s o o f f w w a a r r r r a a n n t t y y
The use of an MESys boiler with a storage or conveyor
system from another manufacturer is not permissible
and will result in voiding your warranty along with
undependable operation.

8.1 Pellet storage room

The auger extraction system is part of the MESys pellet heating system. The sloping base is to be provided by
the customer. Information and important notes on setting up storage rooms can be found in the MESys plan-
ning documents and at www.oekofen.com.
Information on installing the auger extraction system is included in the auger system installation manual. Re-
fer to the instructions on how to make a sloping base.

8.2 Flexilo fabric tank

The whole fabric tank system is included in the scope of supply. MESys offers various sizes and types. The
fabric tank supplied may vary from the example shown below.
Please refer to the installation instructions supplied for the fabric tank. Note also the instructions on setting
up and filling.
D D A A M M A A G G E E T T O O P P R R O O P P E E R R T T Y Y
Fans should not be used to ventilate the storage room
or boiler room. The use of passove ventilation is re-
quired, or the use of a sophisticated system that bal-
ances outside and inside pressure in the boiler
Installation Manual PELLEMATIC® SmartXS