Stornext M330 San Cabling - Quantum StorNext M330 Hardware Manual

Metadata appliance
Hide thumbs Also See for StorNext M330:
Table of Contents

Advertisement

Chapter 2: Hardware Overview
StorNext M330 Connectivity
Table 6 StorNext M330
Network Configuration
Ethernet
Logical
Port
Ethernet
Number
Port Number
D
N/A
S
eth0
2
eth1
3
eth2
4
eth3
StorNext M330 SAN
Cabling
28
Physical Port
Location
iDRAC Port
Integrated Port 1
Integrated Port 2
Integrated Port 3
Integrated Port 4
Each StorNext M330 MDC node contains one 2-port 8Gb Fibre Channel
(FC) host bus adapter (HBA) card in PCIe expansion slot 3.
Note: If small form-factor pluggable (SFP) FC adapters are needed,
use only Intel-based SFP adapters. SFP adapters from other
vendors are not compatible with the FC HBA card used in the
StorNext M330. Twinax cables have the adapters built into the
end of the cable, so they do not require SFP adapters.
Fibre Channel Zoning
Each Fibre Channel port supports dual-port tape drives and libraries.
StorNext clients should not be zoned to access the tape drives/libraries
unless they are acting as a Distributed Data Mover host.
Separate Fibre Channel zoning is required for tape and disk. If the
system has a tape library, use FC port 1 for disk, and FC port 2 for tape .
The actual zoning configuration for these devices is dependent on
variables such as the Fibre Channel switch vendor, the WWPN of the
HBA ports, and the external hardware.
Port Function
Service
GUI and Management
(Configurable from
Service Menu)
Metadata
(Configurable from
Service Menu)
StorNext M330 Metadata Appliance Hardware Guide
Bond
N/A
N/A
Bond 0
When not bonded, eth2 is usable
and eth3 is not usable
Bond 0
When not bonded, eth3 is not used