6. Operations

6.1 Switch on with "Green Mode" Function

When utility input is connected to the UPS, press "ON" button and keep pressing until the "Bi"
beep stops to turn on the UPS. After that, connect the electrical cords of the equipments that
will be used (such as desktop computer and CRT monitor) to the rear panel of UPS. In order to
save the power, it will also automatically enable the "Green mode" - No Load (or Light load)
shut-down function under backup mode (about 4 minutes later).
ATTENTION: At backup mode, UPS can be automatically shut-down if none of the connected loads
is operating. (Green mode; No Load shut down function) Once the utility power is
normal again, the unit can be waked up by itself.
CAUTION: Never connect a laser printer or plotter to the UPS. A laser printer or plotter draws
significantly more power periodically than its idle status, and may overload the UPS.

6.2 Switch on with "Disabled Green Mode" Function

When utility input is connected to the UPS, press "ON" button and keep pressing until
the "Bi.Bi-Bi" beeps stopped to turn on the UPS. After that, connect the electrical cords of the
equipment that will be used (such as Notebook computer and LCD monitor) to the rear panel
of UPS. If the load is lighter than 30W, please also refer this function to avoid any
inconvenience cause by "Green Mode" function.

6.3 Switch off UPS

Press the "OFF" button at "LINE" or "BACKUP" modes and keep pressing more than 3 second
to turn off the UPS.
ATTENTION: UPS can automatically charge itself under "OFF" mode. (Advanced Battery
Management Technology)

6.4 Silence Function

When UPS is under "BACKUP" mode, press the "SILENCE" button about 1 second to silence
the audible alarm. The function is disabled when UPS is under condition of "LOW BATTERY" or
"OVERLOAD"

6.5 Self-test Function

Press the "TEST" button at "LINE" mode about 0.5 second, UPS will perform self-test
procedure automatically.
ATTENTION: No load shut-down function can be disabled by pressing button until bi-bi beep to
turn on the UPS.

7. Battery Maintenance

WARNING Please read the following cautions before replacing batteries. Servicing of batteries
should always be performed or supervised by personnel knowledgeable of batteries and
required precautions. Keep unknowledgeable (i.e., unauthorized) personnel away from the
batteries.
CAUTION: Except for the battery, the unit contains no user serviceable parts. Repairs should be
performed only by factory trained service personnel.
CAUTION: A battery can present a risk of electrical shock and high short-circuit current. The
following precautions should be observed when working on batteries:
(1) Remove watches, rings, or other metal objects.
(2) Use tools with insulated handles.
CAUTION: Do not dispose of batteries in a fire. The batteries may explode.
CAUTION: Do not open or mutilate batteries. They contain electrolyte are toxic and harmful to the
skin and eyes.
CAUTION: When replacing batteries, use the same number and type of batteries.
© All rights reserved. All trademarks are property of their respective owners.