Membrane Production Calculation - SpectraPure Mega MaxCap Installation And Operating Manual

Reverse osmosis/deionization water purification systems
Table of Contents

Advertisement

SpectraPure

MEMBRANE PRODUCTION CALCULATION:

Membranes produce the rated gallons per day (GPD) at 60 psi (4.1 bars)
operating pressure, 77°F (25°C) operating temperature and with no more
than 250 ppm total dissolved solids.
Membrane output gallons per day (GPD) depends on operating pressure,
water temperature and the TDS in the feed water.
Expected GPD = Rated GPD × PCF × TCF
PCF is the pressure correction factor
TCF is the temperature correction factor
Calculation of Pressure Correction Factor (PCF): The output (GPD) from
the membrane is directly proportional to the applied pressure.
NOTE: The membrane is rated to produce the rated GPD at 60 psi. For any
pressure other than 60 psi the output GPD is multiplied by the PCF.
PCF = Line Pressure (in psi) ÷ 60
Calculation of Temperature Correction Factor (TCF): The output (GPD)
decreases with a decrease in temperature. This is due to water viscosity
increasing with a decrease in water temperature.
Temperature Correction Factor Table (TCF)
°F /°C
41.0 /5
42.8 /6
44.6 /7
46.4 /8
48.2 /9
50.0 /10
51.8 /11
53.6 /12
55.4 /13
57.2/14
SpectraPure
16
TCF
°F /°C
0.521
59.0 /15
0.540
60.8 /16
0.560
62.6 /17
0.578
64.4 /18
0.598
66.2 /19
0.620
68.0 /20
0.640
69.8 /21
0.661
71.6 /22
0.684
73.4 /23
0.707
75.2 /24
(continued on next page)
Inc.
®
480.894.5437 Call us toll-free 1.800.685.2783
2167 East Fifth St, Tempe, Arizona 85281
®
TCF
°F /°C
0.730
77.0 /25
0.754
78.8 /26
0.779
80.6 /27
0.804
82.4 /28
0.830
84.2 /29
0.857
86.0 /30
0.884
87.8 /31
0.912
89.6 /32
0.941
91.4 /33
0.970
93.2 /34
TCF
1.000
1.031
1.063
1.094
1.127
1.161
1.196
1.232
1.267
1.304

Hide quick links: