WARNING
To reduce the risk of burns, electrocution, fire or injury to persons:
1.
Close supervision is necessary when this product is used by, on, or near children or physically incapacitated individuals.
2.
Use this product only for its intended use as described in this guide.
3.
Keep the power cord away from heated surfaces.
4.
Never use while drowsy or asleep.
5.
Do not cover the unit or the AC to DC adapter while power is applied.
6.
Never operate this product if
a.
It has a damaged power cord or plug.
b.
It is not working properly.
c.
It has been dropped or damaged.
d.
It has been dropped into water.
Instead return the product to an authorized DeVilbiss Healthcare service center for examination and repair.
7.
Check the collection container for cracks before each use. Do not use if cracked.
8.
Universal precautions must be observed while providing care or handling equipment for persons with an infectious condition.
9.
Do not place the suction unit in a position that would make it difficult to disconnect the AC power cord.
10. When the device is used under extreme operating conditions and in the carrying case, the surface temperature of the device may exceed 73°C.
11. The suction tube shall be kept isolated from other parts of the system to confirm that it does not exceed 43°C prior to patient contact.

INTERNATIONAL TRAVEL

The 7314 series is equipped with an AC to DC adapter allowing operation on any AC voltage (100-240 VAC, 50/60 Hz). However the correct power cord must be used to
connect to adaptable wall power. AC power is removed by disconnecting the power cord from the AC outlet receptacle.
NOTE– Check power cord for adaptability before using.

INTRODUCTION

Your DeVilbiss suction unit is a compact medical suctioning device which has been designed for reliable, portable operation. Following the recommended operating and
maintenance procedures outlined in this instruction guide will maximize the life of this product. This guide provides an overview of the suction unit and operation. Your
equipment provider should give more detailed instructions related to patient care.
Intended Use Statement
The device is to be used to remove fluids from the airway or respiratory support system and infectious materials from wounds. The device creates a negative pressure
(vacuum) that draws fluids through disposable tubing that is connected to a collection container. The fluids are trapped in the collection container for proper disposal. It is for
use on the order of a physician only.
Contraindications (specific situation in which the device shall not be used)
The Vacu-Aide QSU should not be used for:
thoracic drainage
nasogastric suction
DANGER
The DeVilbiss Vacu-Aide is a vacuum suction device designed for the collection of nonflammable fluid materials in medical applications only. Improper use during
medical applications can cause injury or death. For all medical applications:
1.
All suctioning should be done in strict accordance with appropriate procedures that have been established by a licensed medical authority.
2.
Some attachments or accessories may not fit the tubing supplied. All attachments or accessories should be checked prior to use to assure proper fit.

ACCESSORY/REPLACEMENT ITEMS

The following items can be purchased separately as accessories or replacement items for your 7314 Series DeVilbiss Suction Unit:
Description
6' patient tubing
800 Disposable Container (container and lid only) for use with external bacteria
filter (48 pack)
Collection Container Kit (800 ml disposable container, external bacteria filter,
elbow, 10" and 6'tubing package)
Collection Container Kit (Internal filter cartridge, splash guard, 800 ml
container, 4
" and 6' tubing package)
800 ml disposable container with internal filter cartridge, splash guard and 4
tubing (48 each)
Filter cartridge (12 pack) (For Disposable Container with internal filter)
Collection Container Kit (1200 ml reusable container, external bacteria filter,
elbow, 4
" tubing)
1200 ml reusable container (external bacteria filter, elbow, 4
External bacteria filter (non-sterile) (12 pack) For reusable container and
disposable container with external filter
NOTE– The use of electrical cables and accessories other than those specified in this manual or referenced documents may result in increased electromagnetic emissions
from the product or decreased electromagnetic immunity of the product.
A-7314
Part No. Description
6305D-611
610-48BP
22330
7305D-633 AC to DC adapter/charger
"
7305D-632 Power cord for US
7305D-635 Power cord for Continental Europe
7314D-603 Power cord for UK
" tubing) (6 pack) 7314D-604 Power cord for Australia
7305D-608 Power cord for Japan
Splash Guard (12 pack) for Disposable Container with internal
filter cartridge
Carrying case
12V DC power cord (1 each)
Part No.
7305D-641
7314D-606
7304D-619
7314P-613
DV51D-606
DV51D-607
DV51D-608
DV51D-609
DV51D-613
EN - 3