Application and properties
1.6 Configuration examples
1.6.3

DNP3 / IEC

1.6.3.1

Configuration with 1 subnet

Configuration example with a non-redundant control center
The following example describes a configuration with a non-redundant control center in
which all nodes are located in 1 IP subnet.
In this example, the DNP3 protocol is used; in other words, the stations are equipped with a
CP 1243-1.
A configuration in which the IEC protocol is used would have the same setup.
Figure 1-4
The S7-1200 stations are connected to the Internet via the CP and connected to the control
center.
When using the DNP3 protocol, for example, SIMATIC PCS 7 TeleControl or the system of a
third-party provider can be used as the control center. If you use SIMATIC PCS 7
TeleControl as the DPN3 master in the control center, you require the necessary DPN3
driver.
20
Configuration example with a non-redundant control center and stations in one IP subnet
Operating Instructions, 04/2017, C79000-G8976-C365-03