Sullair ES-6 Series User Manual page 55

Standard&24kt 5, 7.5 and 10hp/4, 5.5 and 7.5 kw
Hide thumbs Also See for ES-6 Series:
Table of Contents

Advertisement

3.20 ID, WIRING DIAGRAM—SRS 25-100 115-230V/1/60
ELECTRICAL SPECIFICATIONS
COMPRESSOR - UN 115V 1PH 60HZ
SRS-25 FLA 4.32 0.41KW
SRS-35 FLA 4.32 0.41KW
SRS-50 FLA 7.31 0.651KW
SRS-75 FLA 9.23 0.809KW
SRS-100 FLA 11.44 1.082KW
COMPRESSOR - UN 23-V 1PH 60HZ
SRS-100 FLA 5.72 1.082 KW
NOTES:
1. BY INSTALLER -
OF RESIDUAL CURRENT AUTOMATIC CIRCUIT BREAKER
FAN MOTOR - UN 115V 1PH 50-60HZ
FLA 0.46 0.035KW
FLA 0.46 0.035KW
FLA 1.00 0.076KW
FLA 1.00 0.076KW
FLA 1.00 0.076KW
FAN MOTOR - UN230V 1PH 50-60HZ
FLA 0.50 0.076KW
COMPONENT DESCRIPTION
QS
MAIN SWITCH
CN
ELECTRIC DRAIN POWER SUPPLY
MC
COMPRESSOR MOTOR
EV
FAN MOTOR
SK
COMPRESSOR OVERLOAD PROTECTOR
KA
STARTING RELAY
C
COMPRESSOR START CAPACITOR
TV
FAN THERMOSTATIC SWITCH
HT
HIGH TEMPERATURE SAFETY SWITCH
ELECTRICAL SUPPLY LINE
1 PHASE + NEUTRAL + PROTECTION EARTH
CABLES SIZE
3G16AWG

Advertisement

Table of Contents