Sullair ES-6 Series User Manual page 53

Standard&24kt 5, 7.5 and 10hp/4, 5.5 and 7.5 kw
Hide thumbs Also See for ES-6 Series:
Table of Contents

Advertisement

3.19 ID, WIRING DIAGRAM—DUAL CONTROL WYE-DELTA
PRIMARY
VOLTS
TAPS
220
H1-H2
4--
H1-H4
NOTES:
1. TO TERMINAL STRIP < 4, 5, 6 < STOP , START < REMOTE
STOP/START BY CUSTOMER (REMOVE 4-5 JUMPER)
2. REMOVE JUMPERS 6-7 AND 9-2 FOR CONNECTION TO
BASE/LOAD SEQUENCE CONTROL.
COMPRESSOR TERMINAL = 6, 7, 9, 2
BASE/LOAD CONTROL = 116, 117, 118, 119
STARTER
LOW
HIGH JOIN
SECONDARY
VOLTS
TAPS
110
X1-X3
115
X1-X3
12 LEAD MOTOR CONNECTIONS
T1
T2
T1, T7
T2, T8
T1 T4 - T7
T2 T5 - T8
1M
WYE-DELTA
1MOL
MOTOR-STARTER OVERLOAD NO
CONTACT
1MTR
WYE-DELTA TRANSITION TIMER RELAY
2M
WYE-DELTA TRANSITION COIL
S
WYE-DELTA START COIL
1CR
RUN CONTROL RELAY
2CR
POWER FAILURE RESTART RELAY
H
HOURMETER
LT1
POWER ON LIGHT
PSW1
SUMP PRESSURE SWTICH
PSW2
LINE PRESSURE SWITCH, (SET PER FACE
OF ORDER)
SOL1
LOAD CONTROL SOLENOID VALVE
SS1
HAND/OFF/AUTO SELECTOR SWITCH
TSW1
UNIT DISCHARGE TEMPERATURE
SWITCH
CB1
CIRCUIT BREAKER TANSFORMER
PRIMARY
CB2
CIRCUIT BREAKER TRANSFORMER
SECONDARY
CPT
CONTROL POWER TRANSFORMER 110-
120VAC SECONDARY SEE
TRANSFORMER LABEL FOR PROPER
CONNECTIONS
T3
T4
T3, T9
T4, T10
T3 T6 - T9
T10
T5
T6
T5, T11
T6, T12
T11
T12

Advertisement