Sullair ES-6 Series User Manual page 71

Standard&24kt 5, 7.5 and 10hp/4, 5.5 and 7.5 kw
Hide thumbs Also See for ES-6 Series:
Table of Contents

Advertisement

SECTION 6
M
P
/C
INIMUM
RESSURE
HECK
Refer to Figure 6-4. Minimum pressure/check valve
maintenance is minimal. The only parts which
normally require replacement are the o-ring seal
around the piston and the valve seat on the check
valve. To replace any of the two parts, follow the
procedure explained below.
WARNING
Before doing compressor maintenance, dis-
connect compressor from power source
and lock out power source. Isolate com-
pressor from line pressure by closing rec-
ommended discharge shut-off valve and
releasing all internal pressure from com-
pressor.
WARNING
Assure that line pressure gauge on com-
pressor indicates "ZERO" pressure before
any work is done. Failure to comply can
cause injury.
1. Unscrew the minimum pressure valve from
the drive housing.
2. Remove all parts.
3. Clean and inspect all parts.
4. Remove the screw holding the check valve
seat. Replace valve seat. Reinstall securing
with Loctite® #222.
5. Install new o-ring. Before reinstallation, lubri-
cate with Parker Super "O" ring seal or an
equivalent grease.
6. Reinstall the whole valve assembly. Tighten
and secure.
V
M
ALVE
AINTENANCE
Figure 6-4: Minimum Pressure/Check Valve
(P/N 604131)
1.Valve
2. O-Ring (I)
Spring
4. Screw
5. Valve
Seat (I)
(I) Repair Kit P/N 250030-226
T
A
M
HERMOSTAT
CTUATOR
Refer to Figure 6-5. The only part which would ever
need replacement is the thermostat valve actuator.
For replacement, follow the procedure explained
below.
WARNING
Before doing compressor maintenance, dis-
connect compressor from power source
and lock out power source. Isolate com-
pressor from line pressure by closing rec-
ommended discharge shut-off valve and
releasing all internal pressure from com-
pressor.
1. To prevent spillage and loss of re-usable
fluid, place a contaminate-free fluid recepta-
cle beneath fluid drain valve and fluid filter.
2. Drain fluid by removing fluid drain cap at tee
located beneath compressor.
3. Unscrew and remove hollow hex plug.
4. Remove spring and piston.
5. By using long nosed pliers, pull the actuator
out.
ES-6 USER MANUAL
3. Valve
4. Washer
Stem
6. Check
7. Cap
Spring (I)
AINTENANCE
71

Advertisement

Table of Contents
loading

Table of Contents