Safety Evaluation; Mechanical Inspection; Temperature Control System; Gas Combustion System - Pitco VF35 Installation And Operation Manual

Hide thumbs Also See for VF35:
Table of Contents

Advertisement

This section should ONLY be performed by a qualified service technician as part of a regular kitchen
maintenance program. This inspection should take place a minimum of once a year by an Authorized
Service Technician recommended by Pitco. It may be necessary perform this inspection more than once a
year.

SAFETY EVALUATION

 Check legs, casters, wheels, plate welds and ensure all nuts and bolts are secured.
 Check conditions of flexible gas line and verify appliance retention / lanyard system is in place.

MECHANICAL INSPECTION

 Check frypot for shortening leaks and excessive oil build up
 Check for oil migration (Clean as required)
 Check hood drain cup, ensure it is empty and not dripping into the flue.
 Check hood baffle for clean surface, oil/water condensate can drip on and into the flue.
 Check flue for foreign debris and hood down draft currents.
 Check drain/filtration system (if equipped) for leaks
 Check for missing appliance parts, i.e.: cover strips
 Check for missing fasteners

TEMPERATURE CONTROL SYSTEM

 Check temperature probes and limits for carbon build up and plating. Clean as required
 Check proper mounting of probes and sensors and all fasteners are secure.
 Check thermistor probe resistances for stability.
 Check Controller/thermostat features to ensure they are functioning.
 Check Temperature Calibration

GAS COMBUSTION SYSTEM

 Check for gas leaks.
 Check and clean vent tube on gas control valve pressure regulator.
 Check burners, clean debris and grease from pilot and pilot orifice tips.
 Check and adjust the burner pressure to nameplate reading.
 Check incoming gas pressure to the appliance under static and dynamic conditions.
 Check ignition system and adjust pilot flame as required.
Check flame sensor reading.
Check gap spacing and clean igniter.
 Recheck for gas leaks after inspection.
PITCO VF SERIES INSTALLATION & OPERATIONAL MANUAL
L20-418 Rev 2 (5/16)
21

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vf65

Table of Contents