Chapter 2
Installing the Device
1
Figure 7: Assembling the Failsafe Alarm Relay Terminal Block
1. Pluggable Terminal Block    2. Screw-Type Terminal Block
2.
Connect a failsafe device to the terminal block.
Figure 8: Failsafe Alarm Relay Wiring
1. Pluggable Terminal Block    2. Screw-Type Terminal Block    3. Normally Open Terminal    4. Common Terminal    5. Normally Closed
Terminal
Section 2.5

Connecting Power

The RUGGEDCOM RST2228 supports dual redundant AC and/or DC power supplies that can be installed in any
combination.
The RUGGEDCOM RST2228 can be equipped with either a screw-type or pluggable terminal block, which provides
power to both power supplies. The screw-type terminal block is installed using Phillips screws and compression
plates, allowing either bare wire connections or crimped terminal lugs. Use #6 size ring lugs for secure, reliable
connections under severe shock or vibration.
12
3
4
1
2
5
2
RUGGEDCOM RST2228
Installation Guide
3
5
4
Connecting Power