Chapter 5
Technical Specifications
Section 5.2
Failsafe Alarm Relay Specifications
Maximum Switching Voltage
250 VAC
30 VDC
Section 5.3
Supported Networking Standards
Parameter
IEEE 802.1AB
IEEE 802.1D
IEEE 802.1Q
IEEE 802.1p
IEEE 802.1x
IEEE 802.3
IEEE 802.3u
IEEE 802.3z
IEEE 802.3ab
IEEE 802.3ae
IEEE 802.3x
Section 5.4
Operating Environment
The RUGGEDCOM RST2228 is rated to operate under the following environmental conditions.
Ambient Operating
b
Temperature
Ambient Storage Temperature
Ambient Relative Humidity
Maximum Altitude
b
Measured from a 30 cm (11.8 in) radius surrounding the center of the enclosure.
c
Non-condensing.
32
Rated Switching Current
10 Mbps
100 Mbps
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
-40 to 85 °C (-40 to 185 °F)
-40 to 85 °C (-40 to 185 °F)
c
5% to 95%
3000 m (9842 ft)
2 A @ 250 VAC
2 A @ 30 VDC
1000 Mbps
10000 Mbps
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
RUGGEDCOM RST2228
Installation Guide
Isolation
150 W
500 VA
Notes
Link Layer Discovery Protocol (LLDP)
MAC bridges
VLAN (Virtual LAN)
Priority levels
Port-based network access control
10Base-T
100Base-TX/100Base-FX
1000Base-SX/LX
1000Base-TX
10GBase
Full duplex operation
Failsafe Alarm Relay Specifications