Siemens SIMOTION D4x5 Series Manual page 70

Hide thumbs Also See for SIMOTION D4x5 Series:
Table of Contents

Advertisement

Technical data
5.1 Technical data D4x5
General technical data
Table 5-9
Data
Fan
Power supply
● Rated value
● Permissible
Current
consumption,
typically
Starting current,
typ.
Power loss
1)
Digital inputs
Table 5-10
Data
Digital inputs
Input voltage
● Rated value
● For signal "1"
● For
Galvanic isolation
Current
consumption typ. at
signal level "1"
Input delay, typ.
(hardware)
1)
2)
70
Technical data (general)
SIMOTION
D425
Optional fan/
battery module
24 V DC
20.4 ... 28.8 V
range
600 mA
1)
6 A
15 W
With no load on inputs/outputs, no 24 V supply via DRIVE‑CLiQ and PROFIBUS interfaces
Digital inputs on SIMOTION D4x5
SIMOTION D425
8
24 V DC
15 ... 30 V
-3 ... +5 V
signal "0"
2)
Yes, in groups of 4
10 mA at 24 V
L -> H: 50 µs
H -> L: 150 µs
Reference potential is terminal G1 or G2
The digital inputs are protected against polarity reversal up to -30 V
SIMOTION
SIMOTION
D435
D445
Optional fan/
Fan/battery
battery module
module included in
scope of delivery
24 V DC
24 V DC
20.4 ... 28.8 V
20.4 ... 28.8 V
600 mA
2 A
6 A
6 A
15 W
48 W
SIMOTION D435
8
24 V DC
15 ... 30 V
-3 ... +5 V
Yes, in groups of 4
1)
10 mA at 24 V
L -> H: 50 µs
H -> L: 150 µs
SIMOTION
D445‑1
Double fan/
battery module
included in scope
of delivery
24 V DC
20.4 ... 28.8 V
1 A
5 A
24 W
SIMOTION D445/D445‑1
8
24 V DC
15 ... 30 V
-3 ... +5 V
Yes, in groups of 4
1)
10 mA at 24 V
L -> H: 50 µs
H -> L: 150 µs
SIMOTION D4x5
Manual, 04/2014
1)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simotion d425Simotion d445Simotion d435Simotion d445-1