If the configuration word contains some protected items, then you cannot
verify the items after preparing the program. When preparing the program,
the programmer automatically shields the protected items and writes the
other items. Select Security or Protection to write the protected items.
NOTE: If you select None as the Protection option, the system does NOT
carry out an operation when performing Security or Protection.
In some devices, the configuration words cannot be separated, so the system
does not write the configuration word when preparing the program. To write
the configuration word in these cases, select the corresponding item, such as
Write_Option.
Some FLASH devices also use the configuration word for the protect
operation and to execute and display the segment protection.
4.4 Option Menu   
The Option menu includes items to help you program in a specific mode to meet the
targeted system requirements. Before programming a chip, make sure to select the
necessary settings. The General view of the Operation Option screen is illustrated
below. The Operation Option screen includes four tabs:
General
Buffer
Auto.Inc
Count
Each view is explained in the following sections