After you select the device, the software automatically will identify the data buffer type.
You can review the buffer data types if you open the Edit dialog box for the data buffer.
When some file data are loaded into the data buffer, the following rules apply:
With a HEX/ASCII data buffer (EPROM, MCU etc.), the system assumes that
8 bits of the data are valid.
With a JEDEC buffer (PLD/PAL), the system considers the lowest bit (1 bit) of
the file data valid.
Select Load from the File menu to open the Load File dialog box, as illustrated
below. The red labels refer to the numbered notations follow this figure.
1. Buffer. To select the Buffer name from the drop down list. The system loads
the file data into the buffer accordingly.
2. File Name. To enter the name of the data file to load it, or you can select
Browse and choose the file using the Select File box.
3. File Type. To select the type of the file from a drop down list. Different file
types are included here, e.g. Binary, Intel Hex, Motorola S record, JEDEC,
POF, TI, etc.
4. File Mode. To select one of the following File Modes from the drop down list:
28 / 56